Tendon cross‐sectional area on magnetic resonance imaging and anthropometric characteristics can be used to predict insufficient four‐strand hamstring autograft diameter in anterior cruciate ligament reconstruction: A systematic review

Author:

Vivekanantha Prushoth1ORCID,Grzela Patrick1,Wong Stephanie1,Mansour Fadi1,Khalik Hassaan Abdel2,Johnson Jansen2,Hantouly Ashraf3,de SA Darren2

Affiliation:

1. Michael DeGroote School of Medicine, McMaster University Medical Center McMaster University Hamilton Ontario Canada

2. Department of Surgery, Division of Orthopaedic Surgery McMaster University Hamilton Ontario Canada

3. Department of Orthopaedic Surgery, Surgical Specialty Center Hamad Medical Corporation Doha Qatar

Abstract

AbstractPurposeTo evaluate the utility of semitendinosus tendon (ST) and gracilis tendon (GT) cross‐sectional area (CSA) on magnetic resonance imaging (MRI) and anthropometric characteristics in preoperative estimation of graft diameter in patients undergoing anterior cruciate ligament reconstruction (ACLR) with four‐strand hamstring autografts.MethodsThree databases were searched on 29 August 2023. The authors adhered to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta‐Analyses) and R‐AMSTAR (Revised Assessment of Multiple Systematic Review) guidelines and the Cochrane Handbook for Systematic Reviews of Interventions. Data on demographics, anthropometric characteristics, imaging techniques, tendon CSA, correlation coefficients, sensitivities, specificities, regression models and cutoffs for predicting intraoperative graft diameters above 8 mm were recorded.ResultsForty‐six studies comprising 4140 patients were included. Twelve of 19 (63.2%) studies reporting on ST + GT CSA found a moderate to very high correlation with intraoperative graft diameter. Five of 10 (50%) and one of seven (14.3%) studies reporting on ST CSA and GT CSA, respectively, found a moderate to high correlation with intraoperative graft diameter. Cutoffs of ST + GT CSA for predicting graft diameters above 8 mm ranged from 15.8 to 31.2 mm2. Nine of 35 (25.7%) studies that reported on height found a moderate to very high correlation with graft diameter. Seven of 33 (21.2%) studies reporting on weight found a moderate correlation with graft diameter.ConclusionOf the MRI parameters assessed, ST + GT CSA was the most reliable predictor of graft diameter. However, cutoffs, sensitivities, and specificities for predicting diameters above 8 mm were highly variable. Anthropometric characteristics in general were less predictive of graft diameter than MRI parameters. This information can be used by clinicians to predict patients at risk for ACLR failure due to insufficient graft size.Level of EvidenceLevel IV.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3