Eye Lens Dosimetry in Interventional Radiology: Assessment With Dedicated Hp(3) Dosimeters

Author:

Merrachi Nassim-Albert1ORCID,Bouchard-Bellavance Roxanne1,Perreault Pierre1,Gilbert Patrick1,Soulez Gilles12,Bouchard Louis1,Oliva Vincent L.1,Giroux Marie-France1,Normandeau Lysanne1,Therasse Eric12

Affiliation:

1. Department of Radiology, Centre Hospitalier de Université de Montréal, Montreal, Quebec, Canada

2. Centre de recherche, CHUM (CRCHUM), Montreal, Quebec, Canada

Abstract

Purpose: To quantify eye lens dose in interventional radiology and assess whether neck dosimeter is a good surrogate to evaluate eye lens dosimetry. Methods: Radiation exposure was prospectively measured in 9 interventional radiologists between May and October 2017. Standard Hp(0,07) thermoluminescent dosimeters (TLDs) were worn at the neck outside the lead apron, and 2 dedicated eye lens Hp(3) TLDs were placed just above the eyes, one midline and another at the outer edge of the left eye. Correlations between eye lens and neck TLD doses were assessed with Pearson coefficient, and linear regression was used to predict eye lens dose from neck TLD values. Results: Eye lens dose without eye protection was 0.18 ± 0.11 (mean ± standard deviation; 0.08-0.41) mSv per workday and 35.3 ± 6.6 mSv (16.3-82.9) annually (200 workdays/year). Five (56%) radiologists exceeded the 20 mSv annual eye lens dose limit. Eye lens doses from left and central TLDs were 12.46 ± 3.02 and 9.29 ± 3.38 mSv, respectively ( P = .027). Mean eye lens (left and central) and neck TLD doses were 10.87 ± 2.67 and 16.56 ± 5.67 mSv, respectively ( P = .008). Pearson correlation coefficient between both eye lens TLD and between mean eye lens TLD and neck TLD doses were 0.91 and 0.92, respectively. Average of eye lens dose was 0.0179 + (0.5971 × neck dose). Conclusion: Full-time interventional radiologists are likely to suffer from deterministic radiation effects to the eye lens, especially on the left side. Neck TLD significantly overestimates eye lens dose. However, eye lens doses are highly correlated with neck doses and may be predicted from the neck TLD values.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3