T2-PROPELLER Compared to T2-FRFSE for Image Quality and Lesion Detection at Prostate MRI

Author:

Czyzewska Dorota1,Sushentsev Nikita2,Latoch Eryk3,Slough Rhys A.2,Barrett Tristan24

Affiliation:

1. Department of Clinical Physiology, Nuclear Medicine & PET, Rigshospitalet, Copenhagen, Denmark

2. Department of Radiology, Addenbrooke’s Hospital and University of Cambridge, Cambridge, UK

3. Department of Pediatric Oncology and Hematology, Medical University of Bialystok, Poland

4. CamPARI Prostate Cancer Group, Addenbrooke’s Hospital and University of Cambridge, Cambridge, United Kingdom

Abstract

Purpose: The primary objective was to compare T2-FRFSE and T2-PROPELLER sequences for image quality. The secondary objective was to compare the ability to detect prostate lesions at MRI in the presence and absence of motion artefact using the 2 sequences. Methods: 99 patients underwent 3 T MRI examination of the prostate, including T2-FRFSE and T2-PROPELLER sequences. All patients underwent prostate biopsy. Two independent readers rated overall image quality, presence of motion artefact, and blurring for both sequences using a 5-point Likert scale. Scores were compared for the whole group and for subgroups with and without significant motion artefact. Outcome for lesion detection at an MRI threshold of PI-RADS score ≥3 was compared between T2-FRFSE and T2-PROPELLER. Results: The overall image quality was not significantly different between T2-FRFSE and T2-PROPELLER sequences (3.74 vs. 3.93, p = 0.275). T2-PROPELLER recorded a lesser degree of motion artefact (score 4.53 vs. 3.78, p <0.0001), but demonstrated greater image blurring (score 3.29 vs. 3.73, p <0.001). However, in a subgroup of patients with significant motion artefact on T2-FRFSE, the T2-PROPELLER sequence demonstrated significantly higher image quality (3.46 vs. 2.49, p <0.001). T2-FRFSE and T2-PROPELLER showed comparable positive predictive values for lesion detection at 93.2% and 97.7%, respectively. Conclusions: T2-PROPELLER provides higher quality imaging in the presence of motion artefact, but T2-FRFSE is preferred in the absence of motion. T2-PROPELLER is therefore recommended as a secondary T2 sequence when imaging requires repeat acquisition due to motion artefact.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3