Use of a closed system drug-transfer device eliminates surface contamination with antineoplastic agents

Author:

Clark Bernadette A1,Sessink Paul JM2

Affiliation:

1. Oncology, Cleveland Clinic Cancer Center, Fairview Hospital, OH, USA

2. Exposure Control Sweden AB, Bohus-Björkö, Sweden

Abstract

Purpose To evaluate the effectiveness of a closed system drug-transfer device, EquaShield®, at reducing surface contamination with antineoplastic agents throughout an ambulatory cancer chemotherapy infusion center. Methods Surfaces throughout the cancer center were sampled three times. The first samples were obtained in June 2010 without prior cleaning to measure baseline levels of contamination of the current technique (Chemo Dispensing Pin, B. Braun Medical Inc.). The second samples were obtained in August 2010 after the implementation of the closed system drug-transfer device and cleaning to evaluate if the contamination was removed. The third samples were obtained in August 2011. Wipe samples were taken from five positions in the pharmacy and from five positions in the infusion suite. Wipe samples were also collected from two positions in office areas. Samples were analyzed for cyclophosphamide and 5-fluorouracil. Results The results from the first two sets of samples showed contamination with cyclophosphamide on about half of the positions at all locations during both collection periods. However, levels of contamination were very low and mostly just above the detection limit of the analytical method. The highest level of contamination was found on the door and handle in the pharmacy. Contamination with 5-fluorouracil was only observed on the dispensing counter in the pharmacy during the second collection period. The results from the third and final collection period showed no contamination with cyclophosphamide or 5-fluorouracil in the pharmacy, the infusion suite or in offices of the cancer center. Conclusion Implementation of the closed system drug-transfer device for preparing and administering chemotherapy eliminated surface contamination with cytotoxic agents at the ambulatory cancer chemotherapy infusion center.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3