Author:
Sumikawa Satomi,Yakushijin Yoshihiro,Aogi Kenjiro,Yano Takuya,Hiroki ,Hashimoto ,Tsukui Chiyuki,Noguchi Tadashi,Shiraishi Taro,Horikawa Yasuhiro,Yasuoka Yasuo,Tanaka Akihiro,Hidaka Noriaki,Tanaka Mamoru
Abstract
AbstractOccupational exposure of anticancer agents during their preparation has been recognized as a serious hazard. Closed system drug transfer devices (CSTDs) enable “safe” preparation of agents for medical personnel and ensure a safe hospital environment. However, artificial particles of infusion materials have been reported during CSTD use. Here, the incidence of insoluble fine particles during preparation of anticancer agents using CSTDs was examined. Visible insoluble fine particles were found in 465 (9.4%) of 4948 treatment cases at Ehime University Hospital with CSTD use. Contaminants occurred more frequently during preparation of monoclonal antibodies than cytotoxic anticancer agents (19.4% vs. 4.1%, respectively, P < 0.01). A similar survey was conducted at nine hospitals to investigate the incidence of insoluble fine particles with or without CSTDs. Insoluble fine particles were detected in 113 (15.4%) of 732 treatment cases during preparation of monoclonal antibodies with CSTD use. In contrast, the occurrence of insoluble fine particles without CSTDs was found in only 3 (0.073%) of 4113 treatment cases. Contamination with CSTDs might cause harmful effects on patients during cancer therapy. We strongly recommend the use of in-line filters combined with infusion routes after CSTD use to avoid contamination-associated adverse events.
Publisher
Springer Science and Business Media LLC
Reference34 articles.
1. USP Pharmacopoeia Forum. In-Process Revision: <1790> VISUAL INSPECTION OF INJECTIONS (Serial online); 1. Preprint at http://www.usppf.com/pf/pub/index.html (2020)
2. Brewer, J. H. & Dunning, J. H. An in vitro and in vivo study of glass particles in ampules. J. Am. Pharm. Assoc. Am. Pharm. Assoc. 36, 289–293 (1947).
3. DeLuca, P. P., Rapp, R. P., Bivins, B., McKean, H. E. & Griffen, W. O. Filtration and infusion phlebitis: A double-blind prospective clinical study. Am. J. Hosp. Pharm. 32, 1001–1007 (1975).
4. Schroeder, H. G. & DeLuca, P. P. Particulate matter assessment of a clinical investigation on filtration and infusion phlebitis. Am J.. Hosp. Pharm. 33, 543–546 (1976).
5. Falchuk, K. H., Peterson, L. & McNeil, B. J. Microparticulate-induced phlebitis. Its prevention by in-line filtration. N. Engl. J. Med. 312, 78-82 (1985).
Cited by
7 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献