Fatigue Resistance of Two Different Materials Used as Retentive Attachments in Implant Supported Overdenture after Immersion in Denture Cleansing Solution: An In Vitro Comparative Study

Author:

Shinde Akanksha1ORCID,Bulbule Nilesh1,Bhatt Varun1ORCID,Gayathri B.1,Jagtap Amit1

Affiliation:

1. Department of Prosthodontics, Crown and Bridge and Implantology, Dr. D. Y. Patil Dental College and Hospital, Dr. D. Y. Patil Vidyapeeth, Pimpri, Pune, Maharashtra, India

Abstract

Aim: This in vitro study compared the fatigue resistance of two polymeric materials (Nylon and Polytetrafluoroethylene (PTFE)) used as retentive attachments in implant-retained overdentures after immersion in denture cleansing solution. Materials and Methods: A total of 24 samples (N=24), of which 12 capsule-shaped samples of commercially available nylon material from ADIN dental implants, India, and similar sized and shaped 12 PTFE (medical grade) capsules custom fabricated from AAA Industries, Mumbai was obtained. Six samples of each material were immersed in distilled water and six samples in Clinsodent denture cleanser, simulating an 8–h daily immersion of the denture for a period of 2 years. After completion of the immersion protocol, samples were subjected to 2900 fatigue cycles using the Universal Testing Machine (UTM), simulating 4 cycles per day of removal and insertion of the overdenture for a duration of 2 years. Before and after immersion, the wear of the samples was assessed for internal and external diameter changes using the Sipcon Inspection System. The statistical analysis of the obtained results was tested by applying the paired-t test, Fisher analysis of variance, and Tukey’s honest significant difference test, with a probability value less than 0.05 used as statistically significant. Results: Statistically significant differences were observed after immersion in denture cleanser for nylon and PTFE. The greatest fatigue for ID, IHL, and IVL was demonstrated in nylon immersed in Clinsodent at p = .000. ED and EHL of PTFE in distilled water showed greater deformation than others ( p = .000). Conclusion: PTFE attachments have shown better fatigue resistance after immersion in Clinsodent denture cleanser. Nylon material immersed in distilled water as well as in Clinsodent cleanser showed greater deformation after fatigue cycles.

Publisher

SAGE Publications

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3