INFLUENCE OF DIFFERENT IMPLANT ABUTMENT CONNECTION DESIGNS ON ABUTMENT SCREW LOOSENING IN DENTAL IMPLANT SYSTEMS – A SYSTEMATIC REVIEW.

Author:

Kulkarni Dr. Prerna N,Bulbule Dr. Nilesh S,Kakade Dr. Dilip M,Mondal Dr. Shalu S,Bhandari Dr. Akanksha

Abstract

Background: Dental implants have provided an alternative method of prosthetic rehabilitation with high long-term success rates. However, mechanical or biological complications may occur with implants amongst which loosening of the screw is very common. Loosening of the screw might cause misfit of implant‒abutment interface and may occur due to preload loss subsequent to inadequate  initial torque, distortion of the screw, wear of the screw, overloading, and micro-movements because of functional loading. The implant-abutment connection design like internal hex, external hex and morse taper may affect the screw stability. The effect of various implant-abutment connections on the stability of abutment screw has been discussed in this systematic review. Aim: The aim of this review is to assess and compare effect of different abutment connections on loosening of the screw. Data Sources: An online search was made for the articles using Google Scholar and PubMed. Study Eligibility Criteria: Articles published in English language or those articles that have a detailed summary in English language were included. Articles published between 1st January 2000 and 30th September 2018 were selected. Scientific research papers, Randomized controlled trials were included with data on the effect of various implant abutment connections on the loosening of the screw. Results: Out of 449 articles that were identified through electronic database searching. 19 articles were selected. These articles were screened for duplicates and 7 articles were obtained after eliminating the duplicates. None were excluded after screening of the duplicate articles. This review provides an understanding of effect of various abutment connections on loosening of the screw. Limitations: Few articles do not give concrete conclusions due to smaller sample sizes, differences inter-study sample population, variety of groups compared. Conclusions: Out of all studies that were evaluated few stated that internal hex connection design had least screw loosening compared to external hex and morse taper while the other studies were inconclusive. Keywords: Dental Implant, Implant-Abutment Connection, Screw Loosening

Publisher

CAB PUBLISHER

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3