Office-Based 532-nm Pulsed KTP Laser Treatment of Glottal Papillomatosis and Dysplasia

Author:

Zeitels Steven M.,Akst Lee M.,Burns James A.,Hillman Robert E.,Broadhurst Matthew S.,Anderson R. Rox

Abstract

Objectives: Treatment of glottal papillomatosis and dysplasia was mirror-guided and done in surgeons' offices in the 19th century. It migrated to the operating room in the 20th century to accommodate direct laryngoscopic surgery, which required assistants to administer anesthesia and procedural support. The primary treatment goals, which are disease regression and voice restoration and/or maintenance, are tempered by the morbidity of general anesthesia and potential treatment-induced vocal deterioration. To obviate general anesthesia, office-based laser laryngeal surgery was first done in 2001 with the 585-nm pulsed dye laser (PDL), because it employs a fiber delivery system and its energy is selectively absorbed by oxyhemoglobin. Since then, this new angiolytic laser treatment paradigm has become a mainstay of management for many surgeons; however, there are a number of shortcomings of the PDL. To further develop this concept and address the limitations of the PDL, we used a 532-nm pulsed potassium titanyl phosphate (KTP) laser. Methods: A prospective assessment was performed on 48 patients in 72 cases of recurrent glottal dysplasia (36) or papillomatosis (36). All individuals had previously undergone microlaryngoscopic management with histopathologic evaluation. Results: Two dysplasia patients did not tolerate the procedure. Of the treatable dysplasia cases, there was follow-up in 29 of 34. Disease regression was at least 75% in 18 of 29 cases (62%), 50% to 75% in 7 of 29 (24%), and 25% to 50% in the remaining 4 of 29 (14%). Papilloma patients returned for treatment when symptoms recurred, so disease regression could not be assessed accurately. Similar to data obtained with the PDL, these data confirmed that dysplastic mucosa could normalize without resection. Conclusions: Our observations revealed that the 532-nm pulsed KTP laser provided enhanced performance over the PDL laser in a number of ways. The ability to use smaller glass fibers precluded mechanical trauma to the channels of the flexible laryngoscopes and allowed for improved suctioning of secretions. Oxyhemoglobin absorbs energy better at 532 nm than at 585 nm, and the KTP laser can be delivered through a longer pulse width. These factors provide enhanced hemostasis and improved intralesional energy absorbance. Finally, unlike the PDL, the KTP laser is a solid-state laser and is not prone to mechanical failure.

Publisher

SAGE Publications

Subject

General Medicine,Otorhinolaryngology

Reference13 articles.

1. MacKenzie M. The use of the laryngoscope in diseases of the throat with an appendix on rhinoscopy. London: J & A Churchill, 1865: 121–8.

2. Kirstein A. Autoscopy of the larynx and trachea (direct examination without mirror). Philadelphia, Pa: FA Davis Co, 1897: 47–54.

Cited by 190 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3