Detection of multiple sclerosis lesions in the cervical cord: which of the MAGNIMS ‘mandatory’ non-gadolinium enhanced sagittal sequences is optimal at 3T?

Author:

Chang Chian A1,Chong Abigail L1,Chandra Ronil V12,Butler Ernest3,Rajendran Deepa3,Chuah Kenneth1ORCID,Stuckey Stephen12ORCID

Affiliation:

1. Monash Imaging, Monash Health, Melbourne, Australia

2. Faculty of Medicine, Nursing and Health Sciences, Monash University, Melbourne, Australia

3. Department of Neurology, Monash Health, Melbourne, Australia

Abstract

Background and purpose The magnetic resonance imaging in multiple sclerosis consensus guidelines currently mandate three sagittal non-contrast enhanced sequences of T2-weighted fast spin echo, proton density-weighted fast spin echo and short tau inversion recovery; however, these particular three sequences have not previously been compared at 3T. This study compared T2-weighted fast spin echo, proton density-weighted fast spin echo, short tau inversion recovery as well as the double inversion recovery sequence for the sagittal detection of multiple sclerosis lesions in the cervical spinal cord at 3T. Methods Nineteen multiple sclerosis patients underwent magnetic resonance imaging with 3T sagittal T2-weighted fast spin echo, proton density-weighted fast spin echo, short tau inversion recovery and double inversion recovery between November 2012 and April 2013. Two neuroradiologists independently reviewed the images, and the number of lesions detected on each sequence was recorded. Lesion conspicuity was quantitatively assessed with the lesion-to-cord-contrast ratio and lesion contrast-to-noise ratio. The Wilcoxon signed rank test was performed for statistical analysis. Results Proton density-weighted fast spin echo and short tau inversion recovery detected 32% more lesions compared to T2-weighted fast spin echo, and 37% more lesions compared to double inversion recovery. The lesion-to-cord-contrast ratio was highest in short tau inversion recovery, while the lesion contrast-to-noise ratio was highest for proton density-weighted fast spin echo. Conclusions This study provides the necessary evidentiary support at 3T for the magnetic resonance imaging in multiple sclerosis spinal magnetic resonance imaging protocol consensus guidelines. At 3T sagittal proton density-weighted fast spin echo and short tau inversion recovery sequences allowed improved detection of cervical spinal cord multiple sclerosis lesions, compared to T2-weighted fast spin echo and three-dimensional double inversion recovery magnetic resonance imaging. Utilising T2-weighted fast spin echo alone at 3T is insufficient for lesion detection.

Publisher

SAGE Publications

Subject

Clinical Neurology,Radiology Nuclear Medicine and imaging,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3