No difference in whole-blood metal ions between 32-mm and 36- to 44-mm femoral heads in metal-on-polyethylene total hip arthroplasty: a 2-year report from a randomised control trial

Author:

Bunyoz Kristine I1ORCID,Tsikandylakis Georgios23ORCID,Mortensen Kristian1,Gromov Kirill1,Mohaddes Maziar23,Malchau Henrik34,Troelsen Anders1

Affiliation:

1. Department of Orthopaedic Surgery, Copenhagen University Hospital, Hvidovre, Denmark

2. Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden

3. Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden

4. Harris Orthopaedic Laboratory, Department of Orthopaedics, Massachusetts General Hospital, Boston, USA

Abstract

Aim: To investigate the effect of femoral head size on blood metal-ion levels caused by taper corrosion in metal-on-polyethylene total hip arthroplasty, comparing 36- to 44-mm heads with 32-mm heads. Methods: In a randomised, controlled, single-blinded trial, 96 patients were allocated to receive either a 32-mm metal head or the largest possible metal head (36–44 mm) that could be accommodated in the thinnest available vitamin E, cross-linked polyethylene insert. Blood metal ion levels were collected at 1- and 2-year follow-ups. Results: At 1-year, metal-ion levels did not differ between the groups. The median (interquartile range) blood-ion levels for the 32-mm versus the 36- to 44-mm group were 0.11 µg/L (0.08–0.15) versus 0.12 µg/L (0.08–0.22), p = 0.546, for cobalt, 0.50 µg/L (0.50–0.59) versus 0.50 µg/L (0.50–1.20), p = 0.059, for chromium and 1.58 µg/L (1.38–2.05) versus 1.48 µg/L (1.14–1.87), p = 0.385, for titanium. At 2 years, there was no difference either and the corresponding values were 0.15 µg/L (0.12–0.24) versus 0.18 µg/L (0.12–0.28), p = 0.682 for cobalt, 0.50 µg/L (0.50–0.50) versus 0.50 µg/L (0.50–0.57), p = 0.554, for chromium and 1.54 µg/L (1.16–1.87) versus 1.42 µg/L (1.01–1.72), p = 0.207 for titanium. Conclusions: The use of the largest possible metal head (36–44 mm) compared to a 32-mm head in metal–on-polyethylene bearings does not appear to elevate blood metal-ion levels up to 2 years postoperatively. As taper corrosion is probably time-dependent, longer-term reports are needed to evaluate the association between large metal heads and blood metal ion levels. Trial registration: ClinicalTrials.gov (reg. ID NCT0231 6704)

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3