Head size in primary total hip arthroplasty

Author:

Tsikandylakis Georgios123,Mohaddes Maziar123,Cnudde Peter234,Eskelinen Antti56,Kärrholm Johan123,Rolfson Ola123

Affiliation:

1. Department of Orthopaedics, Sahlgrenska University Hospital, Gothenburg, Sweden

2. Department of Orthopaedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden

3. Swedish Hip Arthroplasty Register, Gothenburg, Sweden

4. Department of Orthopaedics, Prince Philip Hospital, HDUHB, Wales

5. Coxa Hospital for Joint Replacement, Tampere, Finland

6. Finnish Arthroplasty Register, Helsinki, Finland

Abstract

The use of larger femoral head size in total hip arthroplasty (THA) has increased during the past decade; 32 mm and 36 mm are the most commonly used femoral head sizes, as reported by several arthroplasty registries. The use of large femoral heads seems to be a trade-off between increased stability and decreased THA survivorship. We reviewed the literature, mainly focussing on the past 5 years, identifying benefits and complications associated with the trend of using larger femoral heads in THA. We found that there is no benefit in hip range of movement or hip function when head sizes > 36 mm are used. The risk of revision due to dislocation is lower for 36 mm or larger bearings compared with 28 mm or smaller and probably even with 32 mm. Volumetric wear and frictional torque are increased in bearings bigger than 32 mm compared with 32 mm or smaller in metal-on-cross-linked polyethylene (MoXLPE) THA, but not in ceramic-on-XLPE (CoXLPE). Long-term THA survivorship is improved for 32 mm MoXLPE bearings compared with both larger and smaller ones. We recommend a 32 mm femoral head if MoXLPE bearings are used. In hips operated on with larger bearings the use of ceramic heads on XLPE appears to be safer. Cite this article: EFORT Open Rev 2018;3 DOI: 10.1302/2058-5241.3.170061.

Publisher

Bioscientifica

Subject

Orthopedics and Sports Medicine,Surgery

Reference59 articles.

1. No authors listed. Swedish Hip Arthroplasty Register. Annual report; 2015. https://registercentrum.blob.core.windows.net/shpr/r/Annual-Report-2015-H19dFINOW.pdf (date last accessed 16 January 2018).

2. No authors listed. Danish Hip Arthroplasty Register. Annual report 2016. http://danskhoftealloplastikregister.dk/wp-content/uploads/2015/11/DHR-%C3%A5rsrapport-2016.pdf (date last accessed 16 January 2018).

3. No authors listed. The Norwegian Arthroplasty Register. Annuar Report 2016. http://nrlweb.ihelse.net/eng/Rapporter/Report2016_english.pdf (date last accessed 16 January 2018).

4. No authors listed. LROI Report 2014. Arthroplasty in the Picture. Annual Report of the Dutch Arthroplasty Register (Landelijke Registratie Orthopedische Implantaten); 2014. https://www.lroi.nl/downloads/9/Report%20LROI%202014%20English.pdf (date last accessed 16 January 2018).

5. No authors listed. Endoprothesenregister Deutschland (EPRD). Jahresbericht 2015. https://www.eprd.de/fileadmin/user_upload/Dateien/Publikationen/Berichte/EPRD-Jahresbericht_2015_FINAL_Web.pdf (date last accessed 16 January 2018).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3