Are single plane intraoperative and biplanar postoperative radiographic measurements of acetabular cup position the same?

Author:

Harold Ryan E1,Delagrammaticas Dimitri1,Keller Tyler1,Butler Bennet1,Stover Michael D1,Manning David W1

Affiliation:

1. Department of Orthopaedic Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL, USA

Abstract

Purpose: Supine positioning and the use of fluoroscopy during direct anterior approach total hip arthroplasty (DAA THA) have been reported to improve acetabular component positioning. This study aims to compare 2-dimensional intraoperative radiographic RadLink measurements of acetabular component position with 3-dimensional postoperative 3D SterEOS measurements. Methods: Intraoperative fluoroscopy and RadLink (El Segundo, CA, USA) were used to measure acetabular cup position intraoperatively in 48 consecutive patients undergoing DAA THA. Cup position was measured on 6-week postoperative standing EOS images using 3D SterEOS software (EOS Imaging, SA, Paris, France) and compared to RadLink findings using Student’s t-test. Safe-zone outliers were identified. We evaluated for measurement difference of > +/– 5°. Results: RadLink acetabular cup abduction measurement (mean 43.0°) was not significantly different than 3D SterEOS in the anatomic plane (mean 42.6°, p = 0.50) or in the functional plane (mean 42.7°, p = 0.61). RadLink acetabular cup anteversion measurement (mean 17.9°) was significantly different than 3D SterEOS in both the anatomic plane (mean 20.6°, p = 0.022) and the functional plane (mean 21.2°, p = 0.002). RadLink identified 2 cups outside of the safe-zone. However, SterEOS identified 12 (anatomic plane) and 10 (functional plane) outside of the safe-zone. In the functional plane, 58% of anteversion and 92% of abduction RadLink measurements were within +/– 5° of 3D SterEOS. Conclusions: Intraoperative fluoroscopic RadLink acetabular anteversion measurements are significantly different than 3D SterEOS measurements, while abduction measurements are similar. Significantly more acetabular cups were noted to be outside of the safe-zone when evaluated with 3D SterEOS versus RadLink.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3