Abstract
AbstractAccurate component orientation and restoration of hip biomechanics remains a continuing challenge in total hip arthroplasty (THA). The goal of this study was to analyze the accuracy/reproducibility of a novel CT-free and pin-less robotic-assisted THA (RA-THA) platform compared to manual THA (mTHA). This matched-pair cadaveric study compared this RA-THA system to mTHA (n = 33/arm), both using the assistance of fluoroscopic imaging, in a group of 14 high-volume arthroplasty surgeons. In both groups, surgeons were asked to aim for 40°/15° for cup inclination/version, and 0 mm of leg length discrepancy (LLD). A validated and accurate method using radio-opaque markers measured cup inclination/version and LLD. The accuracy and reproducibility (fewer outliers) of cup inclination was significantly improved in the robotic group (1.8° ± 1.3° vs 6.4° ± 4.9°, respectively, robotic vs manual; p < 0.001), with no significant difference between groups for version. The reproducibility of LLD was significantly improved in the robotic group (p = 0.003). For all parameters studied, the robotic group had an improved accuracy and lower variance (fewer outliers). The percentage of cases within the more restrictive Callanan safe zone was 100% for RA-THA vs 73% for mTHA (p = 0.002). The CT-free RA-THA platform, using only fluoroscopic imaging, demonstrated more accurate acetabular cup positioning, when compared to the mTHA procedures performed by high-volume hip surgeons (naive to this RA-THA platform), with respect to cup inclination and placement within the Lewinnek/Callanan safe zones. Future study must incorporate economic factors, lower volume surgeons, clinical and patient-centric outcomes, and other radiographic parameters in controlled studies in large sample sizes.
Publisher
Springer Science and Business Media LLC
Subject
Health Informatics,Surgery
Reference38 articles.
1. Barrack RL (2003) Dislocation after total hip arthroplasty: implant design and orientation. J Am Acad Orthop Surg 11:89–99
2. Renkawitz T, Haimerl M, Dohmen L, Gneiting S, Lechler P, Woerner M, Springorum HR, Weber M, Sussmann P, Sendtner E, Grifka J (2012) The association between femoral tilt and impingement-free range-of-motion in total hip arthroplasty. BMC Musculoskelet Disord 13:65
3. Kennedy JG, Rogers WB, Soffe KE, Sullivan RJ, Griffen DG, Sheehan LJ (1998) Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty 13:530–534
4. El Bitar YF, Stone JC, Jackson TJ, Lindner D, Stake CE, Domb BG (2015) Leg-length discrepancy after total hip arthroplasty: comparison of robot-assisted posterior, fluoroscopy-guided anterior, and conventional posterior approaches. Am J Orthop (Belle Mead NJ) 44:265–269
5. Capón-García D, López-Pardo A, Alves-Pérez MT (2016) Causes for revision surgery in total hip replacement. A retrospective epidemiological analysis. Rev Esp Cir Ortop Traumatol 60:160–166
Cited by
22 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献