Risk of subsidence and peri-prosthetic fractures using collared hydroxyapatite-coated stem for hip arthroplasty in the elderly

Author:

Syed Farhan1,Hussein Amr1,Katam Krishnaiah1,Saunders Paul1,Young Stephen K1,Faisal Mohammad1

Affiliation:

1. Trauma and Orthopaedics, Warwick Hospital, UK

Abstract

Introduction: Subsidence has been noted with both cemented and uncemented stems in hip arthroplasty. On most occasions, it’s minimal (i.e. less than 2 mm) and stabilises at 1 year. However, when its progressive and significant, it causes loss of length and horizontal offset, and when symptomatic warrants a revision. Materials and methods: A retrospective radiological review of the patient database was carried out to identify all patients with age ≥ 70 years who underwent elective hip arthroplasty using uncemented HA coated collared stem and had radiographs at 1 year follow up. A total of 176 patients were identified from January 2009 to June 2010. 2 independent investigators classified the proximal femur based on Dorr type and calculated the subsidence based on Engh and Massin method of calculating the distance between the tip of greater trochanter and shoulder of the prosthesis. Results: 7 patients (4 Bs, 2 As, 1 C) had a subsidence of ≥ 2 mm (2–3.2 mm) at 1 year. None of them was symptomatic. 1 of them was secondary to a missed calcar crack and continued to subside for 9 mm before it stabilised on the lesser trochanter at 4 years follow up. There were Dorr 22 (12.5%) type A, 147(83.5%) type B and 7(4%) type C. The mean age was 77.4 years (70–91 years) and male: female ratio was 7:15. 3 patients had an intraoperative calcar crack requiring cabling. All were mobilised full weight-bearing postoperatively, and none had a subsidence of >2 mm at 1 year follow-up. Discussion: Our subgroup analysis identified that subsidence can happen when the collar is “non-functional” and the initial press fit of the stem wasn’t achieved. It can also occur in an event of calcar crack, which is missed intraoperatively. In cases of calcar crack which went on to have to cable during the primary procedure, it neither changed the post-operative rehabilitation nor did it show an increased risk of subsidence. Conclusion: A fully hydroxyapatite (HA) coated collared stem, when used in elderly age group for elective THR, has only 2% risk of intraoperative periprosthetic fracture. There’s a 4% risk of radiologically significant subsidence (i.e. ≥2 mm), however, it has not proven to be clinically significant in our study. Dorr canal type had no bearing on either risk of periprosthetic fracture or subsidence. Collared stems did not have a statistically significant difference in risk of subsidence and peri-prosthetic fracture in comparison to un-collared stem, although there was a non-significant trend in favour of collar use.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3