Abstract

The application of three-dimensional printing technologies to metal materials allows us to design innovative, low-weight, patient-specific implants for orthopedic prosthesis. This is particularly true when the reconstruction of extensive metastatic bone defect is planned. Modeling complex three-dimensional-printed highly repetitive trabecular-like structures based on finite elements is computationally demanding, while homogenization algorithms offer the advantage of reduced simulation cost and time, allowing an effective evaluation of new personalized design suitable for clinical needs. This article describes and discusses the implementation of a reliable method for the multiscale modeling of trabecular structures by means of asymptotic expansion homogenization. Following the material characterization of the Ti6Al4V alloy obtained by electron beam melting technology, the asymptotic expansion homogenization was applied to two alternative low-density cell-unit designs. Model predictions demonstrated satisfactory agreement with compressive experimental tests and cantilever bending tests performed on both designs (differences lower than 5.5%). The method was extended to a real patient-specific hemipelvis reconstruction, exploiting the capability of the asymptotic expansion homogenization approach in quantitatively describing the effect of cell-unit designs and three-dimensional-printing stack direction (i.e. cell-unit orientation) both on the overall mechanical response of the implant and on the stress distribution. The hemipelvis implant filled with the higher density cell unit demonstrated to be 14% stiffer than using the lower density one, while changing the cell-unit orientation affected the stiffness up to 10%. The maximum stress values reached at the anchors were affected in a minor extent by the investigated design parameters.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3