Impact of preoperative extracorporeal life support on left ventricular assist device outcomes: A comparative study

Author:

Zhigalov Konstantin1,Szczechowicz Marcin1,Mashhour Ahmed1,Mkalaluh Sabreen1,Safonov Dmitrii1,Enginoev Soslan2,Easo Jerry1,Ennker Juergen1,Eichstaedt Harald C1,Weymann Alexander1

Affiliation:

1. Department of Cardiac Surgery, European Medical School Oldenburg-Groningen, Carl von Ossietzky University Oldenburg, Oldenburg, Germany

2. Federal Center for Cardiovascular Surgery, Astrakhan State Medical University, Astrakhan, Russia

Abstract

Background: To investigate whether preoperative short-term extracorporeal life support therapy in patients undergoing continuous-flow left ventricular assist device implantation has an impact on the outcome regarding survival and adverse events. Methods: Between January 2011 and May 2018, 100 consecutive patients received HeartMate II, HeartWare, or HeartMate III for end-stage heart failure. Mean age was 64.2 ± 10.3 years. Three patient groups were identified: without preoperative extracorporeal life support (non-extracorporeal life support group, n = 80), with preoperative extracorporeal life support due to postcardiotomy shock after conventional cardiac surgery (postcardiotomy shock group, n = 9), and with preoperative extracorporeal life support without previous surgery (non-postcardiotomy shock group, n = 11). The primary endpoint was overall survival after device implantation. Secondary endpoints were adverse events during the follow-up period. Results: Survival was significantly different between the groups (p < 0.05): 30-day, 6-month, and 1-year survival rates were 85%, 68%, and 61% for non-extracorporeal life support group; 44%, 22%, and 22% for postcardiotomy shock group; and 45%, 27%, and 24% for non-postcardiotomy shock group, respectively. Furthermore, in both extracorporeal life support groups (postcardiotomy shock and non-postcardiotomy shock), there were a higher incidence (p < 0.05) of postoperative right heart failure (30% vs 66.7% vs 54.5%), acute renal failure requiring dialysis (20% vs 77.8% vs 54.5%), and respiratory failure (31.3% vs 88.9% vs 81.8%). Conclusion: Continuous-flow left ventricular assist device implantation with prior extracorporeal life support appears to have a worse outcome regarding survival, right heart failure, renal and respiratory dysfunction (p < 0.05). Future studies have to be done to evaluate the outcome after extracorporeal life support bridge pre-left ventricular assist device, especially as ultima ratio in postcardiotomy shock patients.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3