The Impact of Obesity on Left Ventricular Assist Device Outcomes

Author:

Zhigalov KonstantinORCID,Sá Michel Pompeu Barros OliveiraORCID,Arjomandi Rad ArianORCID,Vardanyan RobertORCID,Goerdt Lukas,Chrosch Thomas,Zubarevich Alina,Wendt Daniel,Pizanis Nikolaus,Koch Achim,Kamler MarkusORCID,Berger RafalORCID,Schmack Bastian,Ruhparwar Arjang,Popov Aron-FrederikORCID,Weymann Alexander

Abstract

Background and Objectives: The understanding of high body mass index (BMI) and outcomes after Left Ventricular Assist Device (LVAD) implantation continues to evolve and the relationship has not been established yet. In this study, we investigated the effects of obesity (BMI > 30 kg/m2) on post–LVAD implantation outcomes. HeartWare LVAD and Heart Mate III LVAD were implanted. The primary outcome that was measured was mortality (in-hospital and on follow-up). The secondary outcomes that were measured were major adverse events. Materials and Methods: At our institution, the West German Heart and Vascular Center (Essen, Germany), from August 2010 to January 2020, a total of 210 patients received a long-term LVAD. Patients were stratified according to BMI ≥ 30 kg/m2 representing the obesity threshold. The first group (n = 162) had an average BMI of 24.2 kg/m2 (±2.9), and the second group (n = 48) had an average BMI of 33.9 kg/m2 (±3.2). Baseline demographics were analysed alongside comorbidities per group. Results: Overall mortality was not significantly different between the obese group (51.1% n = 24) and the nonobese group (55.2%, n = 85) (p = 0.619). The difference between the mean duration of survival of patients who expired after hospital discharge was insignificant (2.1 years ± 1.6, group 1; 2.6 years ± 1.5, group 2; p = 0.29). In-hospital mortality was unvaried between the two groups: group 1: n = 34 (44% out of overall group 1 deaths); group 2: n = 11 (45.8% out of overall group 2 deaths) (p > 0.05). Postoperative complications were unvaried between the obese and the non-obese group (all with p > 0.05). However, a significant difference was found with regards to follow-up neurological complications (18.5% vs. 37.8%, p = 0.01) and LVAD thrombosis (14.7% vs. 33.3%, p = 0.01), as both were higher in the obese population. Conclusion: Obesity does not form a barrier for LVAD implantation in terms of mortality (in-hospital and on follow up). However, a significantly higher incidence of follow-up LVAD thrombosis and neurological complications has been found in the obese group of patients.

Publisher

MDPI AG

Subject

General Medicine

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3