Preliminary Experimental Study about the Feasibility of Combining Pulsatile Cardiopulmonary Support System and a Membrane Oxygenator

Author:

Nakazawa T.1,Shiono M.1,Inoue T.1,Orime Y.1,Shindo S.1,Sezai Y.1

Affiliation:

1. Second Department of Surgery, Nihon University School of Medicine, Tokyo - Japan

Abstract

A cardiopulmonary support (CPS) device that incorporated a pneumatic ventricular assist device (VAD) and a membrane oxygenator was developed for the support of patients with profound heart and/or respiratory failure. This device has an advantage of being both a pulsatile assist device and membrane oxygenator. A “triple flow” regulator was included in this system to control the blood flow through the oxygenator. The purpose of this study was to clarify the efficacy of this system in supporting an animal model with combined cardiac and respiratory failure. In vitro tests showed 3.7 L/min of pump flow under 1.6 L/min of oxygen supply to the oxygenator even though there was a 50% clamp of a “triple flow” regulator with sufficient pulsatility. In 14 acute canine experiments, cardiogenic shock and acute respiratory failure were introduced by coronary ligation and mechanical hypoventilation simultaneously. The pump flow was maintaned at 1.95 - 0.6 L/min (average 1.2 L/min) and the driving pressure of the pump was controlled between 200 and 300 mmHg positive pressure and -20 to -50 mmHg negative pressure. The driving rate was fixed at 100 bpm and systolic/diastolic ratio was controlled between 35-50%. The canines were divided into control group (n=4) and pumped group (drained from the right atrium n=7, drained from the left atrium n=3). By using CPS system, flow and aortic pressure recovered to the initial baseline level. Without this support, the canine model could not maintain systemic circulation. In the group drained from right atrium, central venous pressure decreased with the device from 13.9 ± 2.4 to 5.6 ± 1.4 cm H2O (p<0.01), returned to the initial level without this device (p<0.01). In the group drained from left atrium, pulmonary capillary wedge pressure decreased from 37.9 ± 4.6 to 20.8 ± 5.7 mmHg (p<0.01), and returned to the initial level without the device, arterial oxygen tension levels increased (p<0.01), and also arterial oxygen saturation levels recovered (p<0.01). The results suggest that the current model of the pulsatile CPS has a potential to support the animal model with combined cardiac and respiratory failure.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials,General Medicine,Medicine (miscellaneous),Bioengineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3