Affiliation:
1. Department of Industrial and Management Systems Engineering University of Nebraska-Lincoln Lincoln, NE 68588-0518
2. W.L. Gore associates Elkton, Maryland
Abstract
The objective of this study was to evaluate a number of inner glove liners used to protect the skin from latex proteins and chemical skin sensitizer found in gloves. A battery of performance tests were used for evaluating the inner gloves. Besides these, objective measurements such as skin temperature, skin conductance, and skin moisture content were measured. A series of subjective discomfort/comfort measures were also taken. Seventeen health care providers participated in this experiment where four liner conditions were evaluated at two temperatures. Some of the measures were recorded before and after the tests, while some other measures were recorded every fifteen minutes. Thus each subject participated in eight trials (4 liners X 2 temperatures). The tests were of two hours duration. Sweat, pegboard test, and discomfort measures were the best discriminators of liners, while the other subjective and objective measures were not.
Subject
General Medicine,General Chemistry
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献