Angioscopic Evaluation of an Endoluminal Aortic Graft: The First Clinical Experience

Author:

Hill Bradley B.1,Neville Richard2,Hyde Gordon L.,Kuo Chien-Suu3,Diethrich Edward B.2

Affiliation:

1. Department of Surgery, University of Kentucky Chandler Medical Center, Lexington, Kentucky

2. Arizona Heart Institute & Foundation, Phoenix, Arizona, USA

3. Department of Cardiology, University of Kentucky Chandler Medical Center, Lexington, Kentucky

Abstract

Purpose: Balloon aortoscopy has been described for viewing aortic endoluminal anatomy and guiding aortic stent placement in animals. We report the first clinical use of this technique to visually inspect the proximal portion of a 1-year-old endovascular aortic graft, its proximal fixation stent, and its relationship to the renal arteries. Methods: The aortoscope is a modified fiber-optic endoscope that is fitted over the lens with a transparent, saline-filled balloon for blood displacement. Its performance was evaluated in a 62-year-old woman who had a Parodi-type Dacron/modified Palmaz stent endoluminal graft implanted to exclude an infrarenal aortic aneurysm in 1994. One year later, during an angioplasty procedure for symptomatic left subclavian and left common iliac artery stenoses, the 1-year-old endoluminal graft was inspected with the balloon-tipped angioscopic assembly. Results: Introduced via the left brachial artery, the aortoscope provided a panoramic view of the endoluminal surface through the solution-filled balloon. The endoluminal aortic graft was clearly identified, as were both renal artery orifices proximal to the graft. The surface of the proximal stent was smooth and without exposed metal. No complications occurred with the angioscopy technique. Conclusions: Aortic angioscopy can be used to evaluate endoluminal aortic grafts and endoluminal anatomy. It provides clear, magnified views that may be useful for guiding precise placement and assessing the function and healing of endoluminal devices in the aorta.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3