Stent Protrusion >20 mm Into the Aorta: A New Predictor for Restenosis After Kissing Stent Reconstruction of the Aortoiliac Bifurcation

Author:

Vértes Miklós1ORCID,Juhász Ildikó Zsófia1,Nguyen Tin Dat2,Veres Dániel Sándor3ORCID,Hüttl Artúr1,Nemes Balázs1,Hüttl Kálmán1,Dósa Edit1

Affiliation:

1. Heart and Vascular Centre, Semmelweis University, Budapest, Hungary

2. Medical Faculty, Semmelweis University, Budapest, Hungary

3. Department of Biophysics and Radiation Biology, Semmelweis University, Budapest, Hungary

Abstract

Purpose: To determine the long-term patency of aortoiliac kissing stents and to identify predisposing factors for the development of in-stent restenosis (ISR). Methods: A retrospective analysis was conducted of 105 patients (median age 60.9 years; 64 women) with symptomatic aortoiliac occlusive disease who had kissing stents implanted between 2001 and 2015. The indication for kissing stents was severe claudication in 91 (86.7%) patients and critical limb ischemia in 14 (13.3%). Lesions were TASC A in 52 (49.5%), B in 29 (27.6%), C in 4 (3.8%), and D in 20 (19%) patients. Twenty-five (23.8%) patients had heavily calcified lesions. In all, 210 stents were deployed [180 (85.7%) self-expanding and 30 (14.3%) balloon-expandable]. Follow-up included clinical evaluation, ankle-brachial index measurement, and duplex ultrasonography. Results: The median follow-up was 45 months. The primary patency rates were 93%, 86%, and 77% at 12, 24, and 60 months, respectively. Significant ISR developed in 23 (21.9%) patients (12 unilateral and 11 bilateral). Univariate Cox regression analysis revealed older age [hazard ratio (HR) 0.5, 95% confidence interval (CI) 0.31 to 0.81, p=0.004] and larger aortic diameter (HR 0.42, 95% CI 0.25 to 0.7, p<0.001) to be variables favoring long-term patency, while a longer aortic stent segment (HR 1.56, 95% CI 1.16 to 2.09, p=0.003) and a larger discrepancy between the summed stent diameters and the aortic diameter (HR 1.64, 95% CI 1.01 to 2.65, p=0.043) were associated with ISR development. Multivariate analysis showed a longer aortic stent segment to be the only significant determinant of ISR (HR 1.44, 95% CI 1.02 to 2.01, p=0.035). Conclusion: The kissing stent technique can be performed with good long-term patency. Patients whose iliac stents protrude too far into the aorta need closer follow-up.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3