Carotid Stenting with Cerebral Protection: First Clinical Experience Using the PercuSurge GuardWire System

Author:

Henry Michel1,Amor Max1,Henry Isabelle1,Klonaris Christos1,Chati Zukaï1,Masson Isabelle1,Kownator Serge1,Luizy François1,Hugel Michèle1

Affiliation:

1. UCCI, Polyclinique, Essey-Ies-Nancy, France

Abstract

Purpose: To study the feasibility and safety of carotid angioplasty and stenting using a new cerebral protection device that temporarily occludes the distal internal carotid artery (ICA). Methods: Forty-eight high-risk patients (39 men, mean age 69.1 ± 8 years, range 54 to 86) with 53 ICA stenoses underwent percutaneous angioplasty and stenting via the femoral approach under cerebral protection afforded by a 0.014-inch GuardWire balloon occlusion device. Mean stenosis was 82.1% ± 9.65% (range 70 to 96) and mean lesion length was 16.0 ± 7.5 mm (range 6 to 50). Thirty-three (62%) lesions were calcified, and 38 (72%) were ulcerated. Thirty-two (60%) of the lesions were asymptomatic. With the occlusion balloon inflated in the distal ICA, the lesion was dilated and stented. The area was cleaned by aspiration and flushed via an aspiration catheter advanced over the wire. Blood samples were collected from the external carotid artery (ECA) and analyzed to measure the size and number of particles collected. Computed tomography and neurological examinations were performed the day after the procedure. Results: Immediate technical success was achieved in all patients with the implantation of 38 Palmaz stents, 8 Expander stents, and 11 Wallstents. Carotid occlusion was well tolerated in all patients but 1 who had multiple, severe carotid lesions and poor collateralization. Mean cerebral flow occlusion time was 346 ± 153 seconds during predilation and 303 ± 143 seconds during stent placement. Total mean flow occlusion time was 542 ± 243 seconds. One immediate neurological complication (transient amaurosis) occurred in a patient who had an anastomosis between the external carotid (EC) and ICA territories. Debris was removed in all patients with a mean 0.8-mm diameter catheter. Conclusion: Cerebral protection with the GuardWire device is easy, safe, and effective in protecting the brain from cerebral embolism. Larger studies are warranted.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3