Do the Advantages of the FiberNet® Embolic Protection Device Translate into Technical Success and Comparable Event Rates in Carotid Artery Stenting?

Author:

D'Souza S.B.1,Slovut D.P.1,Bower T.C.1,Bacharach J.M.1

Affiliation:

1. Department Vascular Surgery, Mayo Clinic; Rochester, Minnesota, USA

Abstract

FiberNet® is a second generation non-conventional embolization protection device (EPD) that purports to offer several advantages: ability to capture debris as small as 40 μm, more flexibility with placement and positioning in curved segments requiring a small landing zone, ability to conform to asymmetric vessels, and improved deliverability. The design features a low profile with large surface area to capture debris. Legitimate concerns include inducement of obstruction or low flow with debris capture and requirements in the IFU to aspirate during re-capture and device removal. Our goal was to compare the results of carotid artery stenting (CAS) using FiberNet® against a multi-center experience of CAS using other filter devices to identify any differences in technical success or event rates. FiberNet® (n=25) results were compared to all CAS cases performed at the Mayo Clinic in Rochester, MN, St Mary's/Duluth Clinic in MN, and North Central Heart Institute in Sioux Falls, SD (n=250) from March 2001 to December 2008. Chi-square or means were used to compare variables, as appropriate. Bivariate logistic regression was used to identify possible correlates of adverse outcome. Statistical significance was set at < 0.05. FiberNet® patients were more likely to be older (78.1+5.4 vs 73.6+9.4, p=0.019), female (48% vs 29%, p=0.047), and have peripheral vascular disease (84.0% vs 37.2%, p=0.025), and less likely to have diabetes (8.0% vs 29.8%, p=0.012) than patients in the comparison group. FiberNet® patients had more lesion calcification (40.0% vs 18.9%, p=0.014) and increased number of type 2 and 3 arches (44.2% vs 73.9%, p=0.006). Procedural success rate was 100% in both groups. None of the FiberNet® patients showed evidence of stagnant flow. The thirty-day outcome for TIA, CVA, or death was 4% in FiberNet® versus 4.8% in the comparison group (p NS). None of the independent variables – age gender, serum creatinine, arch complexity, lesion length, lesion calcium, lesion thrombus, PVD, diabetes, contralateral carotid occlusion, or ipsilateral carotid endarterectomy – predicted adverse events. Although FiberNet® patients had more lesion calcium and more challenging arch anatomy, procedural success and adverse events were comparable between groups. The advantages of FiberNet® can be applied to CAS with good technical results and may be a promising EPD for certain high-risk situations.

Publisher

SAGE Publications

Subject

Clinical Neurology,Radiology Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3