Secondary Fill Minimizes Gutter Size in Chimney EVAS Configurations In Vitro

Author:

van Schaik Theodorus G.1ORCID,Meekel Jorn P.1,Jongkind Vincent2,Lely Rutger J.3,Truijers Maarten1,Hoksbergen Arjan W. J.1,Wisselink Willem1,Blankensteijn Jan D.1,Yeung Kak Khee1

Affiliation:

1. Department of Vascular Surgery, VU University Medical Center, Amsterdam, the Netherlands

2. Department of Surgery, Westfriesgasthuis, Hoorn, the Netherlands

3. Department of Interventional Radiology, VU University Medical Center, Amsterdam, the Netherlands

Abstract

Purpose: To investigate in an in vitro model if secondary endobag filling can reduce gutter size during chimney endovascular aneurysm sealing (chEVAS). Materials and Methods: Nellix EVAS systems were deployed in 2 silicone juxtarenal aneurysm models with suprarenal aortic diameters of 19 and 24 mm. Four configurations were tested: EVAS with 6-mm balloon-expandable (BE) or self-expanding (SE) chimney grafts (CGs) in the renal branches of both models. Balloons were inflated simultaneously in the CGs and main endografts during primary and secondary endobag filling and polymer curing. Computed tomography (CT) was performed immediately after the primary and secondary fills. Cross-sectional lumen areas were measured on the CT images to calculate gutter volumes and percent change. CG compression was calculated as the reduction in lumen surface area measured perpendicular to the central lumen line. The largest gutter volume and highest compression were presented per CG configuration per model. Results: Secondary endobag filling reduced the largest gutter volumes from 99.4 to 73.1 mm3 (13.2% change) and 84.2 to 72.0 mm3 (27.6% change) in the BECG configurations and from 67.2 to 44.0 mm3 (34.5% change) and 92.7 to 82.3 mm3 (11.2% change) in the SECG configurations in the 19- and 24-mm models, respectively. Secondary endobag filling increased CG compression in 6 of 8 configurations. BECG compression changed by −0.2% and 5.4% and by −1.0% and 0.4% in the 19- and 24-mm models, respectively. SECG compression changed by 10.2% and 16.0% and by 7.2% and 7.3% in the 19- and 24-mm models, respectively. Conclusion: Secondary endobag filling reduced paragraft gutters; however, this technique did not obliterate them. Increased CG compression and prolonged renal ischemia time should be considered if secondary endobag filling is used.

Funder

Endologix

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3