Systematic Review of the Current In Vitro Experience of the Endovascular Treatment of Juxtarenal Abdominal Aortic Aneurysms by Fenestrated and Parallel Endografting

Author:

Taneva Gergana T.1ORCID,Mirgolbabaee Hadi2ORCID,Groot Jebbink Erik23ORCID,Reijnen Michel M. P. J.23ORCID,Donas Konstantinos P.1

Affiliation:

1. Department of Vascular and Endovascular Surgery, Asklepios Clinic Langen, University of Frankfurt, Langen, Germany

2. Multi-Modality Medical Imaging (M3I) Group, Technical Medical Centre, University of Twente, Enschede, The Netherlands

3. Department of Surgery, Rijnstate Hospital, Arnhem, The Netherlands

Abstract

Objective: To identify and analyze the published in vitro benchtop experiments for the assessment of endovascular techniques used for the treatment of juxtarenal abdominal aortic aneurysms (jAAAs). Data sources: Scopus, PubMed, and Web of Science. Review methods: A systematic literature search was carried out throughout March 2021 following PRISMA guidelines. Two investigators independently performed title and abstract screening to reveal all benchtop testing evaluating the endovascular treatment of jAAA. Results: A total of 19 studies were included, 8 evaluating fenestrated (FEVAR) and 11 parallel grafts (PGs). FEVAR studies used different custom testing apparatus (n=7) or 3D-printed models (n=1) to analyze dislodgement and migration resistance, misalignment consequences and causation, and bridging stents’ radial force, flareability, fatigue, and fracture resistance. All PG studies used silicone-based models to analyze optimal oversizing, sealing length, gutter behavior, and possible reduction. Test evaluation in FEVAR in vitro testing was based on pullout force analysis (N=5), photo evaluation (n=1), fluoroscopy (n=1), X-rays (n=4), CT analysis (n=3), macro- and microscopic evaluation (n=4), water permeability (n=1), and fatigue simulator testing (n=1), while it was based on CT analysis in all PG studies adding ECG-gate in one study. The most frequently tested devices were Zenit (Cook) (n=7), Endurant (Medtronic) (n=5), and Excluder (Gore) (n=5) as main grafts, and Advanta V12 (n=14) as the bridging device. Conclusions: This systematic review presents a broad analysis of the current in vitro methods evaluating the endovascular treatment of jAAA. Fundamental issues have been benchtop tested in both FEVAR and PGs. The analysis of the included studies allowed to recommend an optimal testing design. In vitro testing is a potential tool to further elucidate points of attention hard to investigate in vivo to finally enhance the endovascular treatment outcomes. Future in vitro studies are needed to evaluate the in vitro performance of all indistinctively used devices in the clinical practice.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,Surgery

Reference42 articles.

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3