Impact of Insertion Technique and Iliac Artery Anatomy on Fenestrated Endovascular Aneurysm Repair

Author:

Crawford Sean A.12ORCID,Doyle Matthew G.23,Amon Cristina H.13,Forbes Thomas L.2

Affiliation:

1. Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario, Canada

2. Division of Vascular Surgery, University Health Network, Peter Munk Cardiac Centre, University of Toronto, Toronto, Ontario, Canada

3. Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada

Abstract

Purpose: To develop a mechanically realistic aortoiliac model to evaluate anatomic variables associated with stent-graft rotation and to assess common deployment techniques that may contribute to rotation. Materials and Methods: Idealized aortoiliac geometries were constructed either through direct 3-dimensional (3D) printing (rigid) or through casting with polyvinyl alcohol using 3D-printed molds (flexible). Flexible model bending rigidity was controlled by altering wall thickness. Three flexible patient-specific models were also created based on the preoperative computed tomography angiograms. Zenith infrarenal and fenestrated devices were used in this study. The models were pressurized to 100 mm Hg with normal saline. Deployments were performed under fluoroscopy at 37°C. Rotation was calculated by tracking the change in position of gold markers affixed to the devices. Results: In the rigid idealized models, stent-graft rotation increased with increasing torsion; torsion levels of 1.6, 2.6, and 3.6 mm−1 had mean rotations of 5.2°±0.03°, 11.2°±4.8°, and 27.6°±13.0°, respectively (p<0.001). In the flexible models, the highest rotation (58°±3.0°) was observed in models with high torsion and high rigidity (7.5 mm−1 net torsion and 254 N·m2 flexural rigidity). No rotation was observed in the absence of torsion. Applying torque to the device during insertion significantly increased stent-graft rotation by an average of 28° across all levels of torsion (p<0.01). Multiple device insertions prior to deployment did not change the observed device rotation. The patient-specific models accurately predicted the degree of rotation seen intraoperatively to within 5°. Conclusion: Insertion technique plays an important role in the degree of stent-graft rotation during deployment. Our model suggests that in vivo correction of device orientation can increase the observed rotation and supports the concept of fully removing the device, adjusting the orientation, and subsequently reinserting. Additionally, increasing iliac artery torsion in the presence of increased vessel rigidity results in stent-graft rotation.

Funder

Canadian Society for Vascular Surgery

Physicians’ Services Incorporated Foundation

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3