THE USE OF AR NAVIGATION IN THE INSTALLATION OF VENTRICULAR DRAINS ON CADAVERIC MATERIAL

Author:

A.A. Artemyev1ORCID,E.Yu. Timofeeva1ORCID,T.S. Mudinov1ORCID,E.V. Blinova1ORCID,F.V. Grebenev1ORCID,D.N. Okishev2ORCID,A.N. Konovalov1ORCID

Affiliation:

1. Federal State Autonomous Educational Institution of Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Health of the Russian Federation (Sechenov University)

2. Federal State Autonomous Institution "National Medical Research Center of Neurosurgery named after Academician N.N.Burdenko" of the Ministry of Health of the Russian Federation

Abstract

Augmented reality (AR) technologies are being actively introduced into medicine. AR can be used as a navigation tool in neurosurgery. The purpose of our study is to evaluate the accuracy of placement of external ventricular drainage, the size of the incision and the duration of this manipulation in an animal model using AR navigation and without its use. A CT scan of an animal model (ram's head) was performed, the results were segmented and loaded into AR-glasses. Participants in the experiment are divided into 2 groups of 5 people each. In the main group, ventricular drainage was placed using AR navigation, in the control group without its use. The average incision size in the non-AR group was 29.58 ± 1.566 mm. In the AR group 29.42 ± 1.279 mm. The differences in the two groups are statistically insignificant (p=0.797). In the AR group, the mean operative time was 10.26 ± 1.121 min. In the group without AR use 13.64 ± 1.588 min. The differences between the groups are statistically significant (p<0.05). In the AR group, drainage was inserted into the ventricle in 47 of 50 cases (94%). In the group without the use of AR in 40 cases out of 50 (80%). These differences are statistically significant (p=0.037). AR navigation does not affect the size of the incision, but increases the accuracy of drainage placement and reduces the duration of the procedure. This shows the possibility of using this technology in clinical practice, however, additional research on the use of AR in phantom models is required.

Publisher

Technomed Holdings LLC

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3