Development and Validation of Simple, Rapid and Sensitive High- Performance Liquid Chromatographic Method for the Determination of Butenafine Hydrochloride

Author:

Ansari Mohammad Javed,Ahmed Mohammed Muqtader,Anwer Md. Khalid,Aldawsari Mohammed F.,Shahrani Saad M. Al,Ahmad Niyaz

Abstract

Aims: The current paper reports a simple, rapid, sensitive, accurate, and precise Reverse-phase high performance liquid chromatography (RP-HPLC) method with wide range of estimation to determine butenafine hydrochloride in nanosponges. This method has been validated as per ICH norms. Study Design:  Experimental design with influence of variables such as mobile phase composition, flow rate, temperature and wavelength on the chromatographic peaks. Place and Duration of Study: Department of Pharmaceutics, College of Pharmacy, Prince Sattam Bin Abdulaziz University, Al-Kharj, Saudi Arabia between Jan 2020 and March 2020. Methodology: Separation was achieved by utilizing the most commonly used reverse phase column (C-18, 5 μm, 150 mm x 4.6 mm) set at 30ºC and quantified by UV detection at 280 nm after isocratic elution from a mobile phase (70:30 v/v of methanol: phosphate buffer pH 3.0) flowing at 1 ml/min. Results: A sharp and symmetrical peak was observed at 4.08 ± 0.01 minutes. The low variation in peak area and retention time (1.12% and 0.29%, respectively) and a high number of theoretical plates (>2000) indicated this method’s efficiency and suitability. The least square linear regression analysis (Y = 9265.5 X + 1961.4) showed excellent correlation (r2 = 0.999 ± 0.0003) between concentration and peak area of butenafine hydrochloride through a wide concentration range of 1–50 µg/ml. The limits of detection and quantification (LOD and LOQ) were 0.18 µg/ml and 0.57 µg/ml, respectively. The assay or determinations were accurate, precise and reproducible with mean accuracy and mean relative standard deviation of precision of 101.53 ± 0.43% and 0.51 ± 0.11% respectively. Conclusion: The developed RP-HPLC method was simple, sensitive, reproducible with wide range of estimation of butenafine hydrochloride in the nanosponges. The proposed method could be used for the analysis of butenafine hydrochloride in the conventional pharmaceutical formulations such as tablets, syrup, creams including novel formulations such as nanoparticles, nanosponges, nanoemulsions. The proposed method overcomes the specificity, sensitivity and reproducibility related issues of ultraviolet-visible spectroscopy.

Publisher

Sciencedomain International

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3