Improved Integrated Robotic Intraocular Snake: Analyses of the Kinematics and Drive Mechanism of the Dexterous Distal Unit

Author:

Jinno Makoto1ORCID,Iordachita Iulian2

Affiliation:

1. School of Science and Engineering, Kokushikan University, Tokyo 154-8515, Japan

2. Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218, USA

Abstract

Retinal surgery can be performed only by surgeons possessing advanced surgical skills because of the small, confined intraocular space, and the restricted free motion of the instruments in contact with the sclera. Snake-like robots may be essential for use in retinal surgery to overcome this problem. Such robots can approach the target site from suitable directions and operate on delicate tissues during retinal vein cannulation, epiretinal membrane peeling, and so on. We propose an improved integrated robotic intraocular snake (I2RIS), which is a new version of our previous IRIS. This study focused on the analyses of the kinematics and drive mechanism of the dexterous distal unit. This unit consists of small elements with reduced contact stress achieved by changing wire-hole positions. The kinematic analysis of the dexterous distal unit shows that it is possible to control the bending angle and direction of the unit by using two pairs of drive wires. The proposed drive mechanism includes a new pull-and-release wire mechanism in which the drive pulley is mounted at a right angle relative to the actuation direction (also, relative to the conventional direction). Analysis of the drive mechanism shows that compared to the previous drive mechanism, the proposed mechanism is simpler and easier to assemble and yields higher accuracy and resolution. Furthermore, considering clinical use, the instrument of the I2RIS is detachable from the motor unit easily for cleaning, sterilization, and attachment of various surgical tools. Analyses of the kinematics and drive mechanism and the basic functions of the proposed mechanism were verified experimentally on actual-size prototypes of the instrument and motor units.

Funder

Foundation for the National Institutes of Health

Publisher

World Scientific Pub Co Pte Ltd

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3