Tele-Operated MRI-Guided Needle Insertion for Prostate Interventions

Author:

Moreira Pedro1ORCID,Kuil Leanne1,Dias Pedro2,Borra Ronald34,Misra Sarthak15

Affiliation:

1. Surgical Robotics Laboratory, Department of Biomechanical Engineering, University of Twente, The Netherlands

2. Department of Biomechanical Engineering, Universidade Nova de Lisboa, Portugal

3. Faculty of Medical Sciences, Department of Nuclear Medicine and Molecular Imaging, University of Groningen and University Medical Center Groningen, The Netherlands

4. Medical Imaging Centre of Southwest Finland, Department of Diagnostic Radiology, Turku University Hospital, Turku, Finland

5. Surgical Robotics Laboratory, Department of Biomedical Engineering, University of Groningen and University Medical Center Groningen, The Netherlands

Abstract

Prostate cancer is one of the leading causes of death in men. Prostate interventions using magnetic resonance imaging (MRI) benefits from high tissue contrast if compared to other imaging modalities. The Minimally Invasive Robotics In An MRI environment (MIRIAM) robot is an MRI-compatible system able to steer different types of needles towards a point of interest using MRI guidance. However, clinicians can be reluctant to give the robot total control of the intervention. This work integrates a haptic device in the MIRIAM system to allow input from the clinician during the insertion. A shared control architecture is achieved by letting the clinician control the insertion depth via the haptic device, while the robotic system controls the needle orientation. The clinician receives haptic feedback based on the insertion depth and tissue characteristics. Four control laws relating the motion of the master robot (haptic device) to the motion of the slave robot (MIRIAM robot) are presented and evaluated. Quantitative and qualitative results from 20 human subjects demonstrate that the squared-velocity control law is the most suitable option for our application. Additionally, a pre-operative target localization algorithm is presented in order to provide the robot with the target location. The target localization and reconstruction algorithm are validated in phantom and patient images with an average dice similarity coefficient (DSC) of 0.78. The complete system is validated through experiments by inserting a needle towards a target within the MRI scanner. Four human subjects perform the experiment achieving an average targeting error of 3.4[Formula: see text]mm.

Publisher

World Scientific Pub Co Pte Lt

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Robotic System for Brachytherapy: Validation in Animal Experiments;2024 9th International Conference on Control and Robotics Engineering (ICCRE);2024-05-10

2. Sensing Technologies for Guidance During Needle-Based Interventions;IEEE Transactions on Instrumentation and Measurement;2024

3. Design and Validation of a Nonparasitic 2R1T Parallel Hand-Held Prostate Biopsy Robot With Remote Center of Motion;Journal of Mechanisms and Robotics;2023-07-20

4. CT/MR-compatible physical human-robotized needle interactions: From modeling to percutaneous steering;Mechatronics;2022-08

5. A review on the techniques used in prostate brachytherapy;Cognitive Computation and Systems;2022-07-11

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3