INTRA-RATER RELIABILITIES AND CONCURRENT VALIDITY OF THE UNIVERSAL GONIOMETER AND TAPE MEASURE FOR MEASURING CERVICAL ACTIVE RANGE OF MOTION

Author:

Adegoke Babatunde Olusola Adeleke1,Offiah Maureen Ngozi2,Okoye Emmanuel Chiebuka3,Akosile Christopher Olusanjo3

Affiliation:

1. Department of Physiotherapy, College of Medicine, University of Ibadan, Ibadan, Nigeria

2. Department of Dermatology, University of Mississippi Medical Centre, Jackson MS 39216, USA

3. Department of Medical Rehabilitation, College of Health Sciences, Nnamdi Azikiwe University, Nnewi, Nigeria

Abstract

Background Data: Cervical active range of motion (cervical AROM) is often assessed in clinical practice to quantify musculoskeletal impairments of the neck and evaluate efficacy of interventions. Such assessment requires instruments with proven reliability and validity. Purpose: To investigate and compare the intra-rater reliabilities and concurrent validity of the universal goniometer and tape measure in measuring cervical AROM. Methods: Cervical AROM in 100 consecutively sampled apparently healthy individuals was measured with both universal goniometer and tape measure and repeated after five days. Data were summarized using descriptive statistics, standard error of measurement, Pearson product moment correlation and intraclass correlation coefficient (ICC) at 0.05 level of significance. Results: Intra-rater reliability of the tape measure (r = 0.28–0.62; ICC = 0.44–0.75) and universal goniometer (r = 0.21–0.67; ICC = 0.34–0.79) were within the acceptable range except for right lateral flexion for goniometer and left lateral flexion for tape measure. Standard errors of measurement were 0.14–0.20 and 0.76–1.27 for tape measure and goniometer, respectively. Concurrent validity coefficients of the two instruments for all cervical AROM (r = 0.23–0.40) except left lateral flexion and right rotation were within the acceptable range. There was no gender difference in cervical AROM using the goniometer but male participants had significantly more range in flexion and right lateral flexion using the tape measure. Conclusions: Tape measure and goniometer have similar intra-rater reliability and significant but weak concurrent validity in assessing cervical AROM except left lateral flexion and right rotation.

Publisher

World Scientific Pub Co Pte Lt

Subject

Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3