Head-Mounted Display for Clinical Evaluation of Neck Movement Validation with Meta Quest 2

Author:

Trinidad-Fernández Manuel12ORCID,Bossavit Benoît3ORCID,Salgado-Fernández Javier4ORCID,Abbate-Chica Susana12,Fernández-Leiva Antonio J.3ORCID,Cuesta-Vargas Antonio I.125ORCID

Affiliation:

1. Grupo de Investigación Clinimetría, Departamento de Fisioterapia, Universidad de Málaga, 29071 Málaga, Spain

2. Instituto de Investigación Biomédica de Málaga y Plataforma en Nanomedicina (IBIMA), Plataforma Bionand, 29590 Málaga, Spain

3. ITIS Software, Departamento de Lenguajes y Ciencias de la Computación, Universidad de Málaga, Andalucía Tech, 29071 Málaga, Spain

4. Departamento de Expresión Gráfica, Diseño y Proyectos, Escuela de Ingenierías Industriales, Universidad de Málaga, 29071 Málaga, Spain

5. School of Clinical Sciences, Faculty of Health, Queensland University of Technology, Brisbane, QLD 4000, Australia

Abstract

Neck disorders have a significant impact on people because of their high incidence. The head-mounted display (HMD) systems, such as Meta Quest 2, grant access to immersive virtual reality (iRV) experiences. This study aims to validate the Meta Quest 2 HMD system as an alternative for screening neck movement in healthy people. The device provides data about the position and orientation of the head and, thus, the neck mobility around the three anatomical axes. The authors develop a VR application that solicits participants to perform six neck movements (rotation, flexion, and lateralization on both sides), which allows the collection of corresponding angles. An InertiaCube3 inertial measurement unit (IMU) is also attached to the HMD to compare the criterion to a standard. The mean absolute error (MAE), the percentage of error (%MAE), and the criterion validity and agreement are calculated. The study shows that the average absolute errors do not exceed 1° (average = 0.48 ± 0.09°). The rotational movement’s average %MAE is 1.61 ± 0.82%. The head orientations obtain a correlation between 0.70 and 0.96. The Bland–Altman study reveals good agreement between the HMD and IMU systems. Overall, the study shows that the angles provided by the Meta Quest 2 HMD system are valid to calculate the rotational angles of the neck in each of the three axes. The obtained results demonstrate an acceptable error percentage and a very minimal absolute error when measuring the degrees of neck rotation; therefore, the sensor can be used for screening neck disorders in healthy people.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference45 articles.

1. Neck Pain: Initial Evaluation and Management;Childress;Am. Fam. Phys.,2020

2. MedlinePlus [Internet] (2022, December 15). Bethesda (MD): National Library of Medicine (US) Neck Injuries and Disorders, Available online: https://medlineplus.gov/neckinjuriesanddisorders.html.

3. The Relationship Between Forward Head Posture and Neck Pain: A Systematic Review and Meta-Analysis;Mahmoud;Curr. Rev. Musculoskelet. Med.,2019

4. The Efficacy of Manual Therapy and Exercise for Treating Non-Specific Neck Pain: A Systematic Review;Hidalgo;J. Back Musculoskelet Rehabil.,2017

5. Javdaneh, N., Saeterbakken, A.H., Shams, A., and Barati, A.H. (2021). Pain Neuroscience Education Combined with Therapeutic Exercises Provides Added Benefit in the Treatment of Chronic Neck Pain. Int. J. Environ. Res. Public Health, 18.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3