A Scalable Lower Bound for the Worst-Case Relay Attack Problem on the Transmission Grid

Author:

Johnson Emma S.12ORCID,Dey Santanu Subhas1ORCID

Affiliation:

1. H. Milton Stewart School of Industrial and Systems Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332;

2. Sandia National Laboratories, Albuquerque, New Mexico 87185

Abstract

We consider a bilevel attacker–defender problem to find the worst-case attack on the relays that control transmission grid components. The attacker infiltrates some number of relays and renders all of the components connected to them inoperable with the goal of maximizing load shed. The defender responds by minimizing the resulting load shed, redispatching using a DC optimal power flow (DCOPF) problem on the remaining network. Though worst-case interdiction problems on the transmission grid have been studied for years, there remains a need for exact and scalable methods. Methods based on using duality on the inner problem rely on the bounds of the dual variables of the defender problem in order to reformulate the bilevel problem as a mixed integer linear problem. Valid dual bounds tend to be large, resulting in weak linear programming relaxations and, hence, making the problem more difficult to solve at scale. Often smaller heuristic bounds are used, resulting in a lower bound. In this work, we also consider a lower bound, but instead of bounding the dual variables, we drop the constraints corresponding to Ohm’s law, relaxing DCOPF to capacitated network flow. We present theoretical results showing that, for uncongested networks, approximating DCOPF with network flow yields the same set of injections and, thus, the same load shed, which suggests that this restriction likely gives a high-quality lower bound in the uncongested case. Furthermore, we show that, in the network flow relaxation of the defender problem, the duals are bounded by one, so we can solve our restriction exactly. Finally, because the big-M values in the linearization are equal to one and network flow has a well-known structure, we see empirically that this formulation scales well computationally with increased network size. Through empirical experiments on 16 networks with up to 6,468 buses, we find that this bound is almost always as tight as we can get from guessing the dual bounds even for congested networks in which the theoretical results do not hold. In addition, calculating the bound is approximately 150 times faster than achieving the same bound with the reformulation guessing the dual bounds.

Publisher

Institute for Operations Research and the Management Sciences (INFORMS)

Subject

General Engineering

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Optimal defense resource allocation against cyber-attacks in distributed generation systems;Proceedings of the Institution of Mechanical Engineers, Part O: Journal of Risk and Reliability;2023-10-26

2. Synthetic Test Case for Ukraine's Power Grid;2023 North American Power Symposium (NAPS);2023-10-15

3. Risk-based contingency analysis for power systems considering a combination of different types of cyber-attacks;Applied Energy;2023-10

4. A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network;IEEE Systems Journal;2023-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3