In the review we discussed about the method of quantitative computed tomography (QCT, quantitative computed tomography). In QCT, X-ray density (HU) is converted to bone mineral density (BMD mg / ml) using linear relationships obtained by scanning calibration standards (phantoms). When compared with the normative age data, it is possible to diagnose osteoporosis (OP). The review presents various QCT techniques and their diagnostic capabilities in accordance with the positions of ISCD 2019 - (International Society for Clinical Densitometry). The results of comparison of QCT and conventional dual-energy X-ray absorptiometry (DXA) are  considered.  It is noted that in the study of the proximal femur (PF), the results of the methods are well comparable, according to the results of both methods, it is possible to diagnose OP by the T-score. However, when examining the spine QCT, the volume BMD of the trabecular bone of the vertebral bodies is assessed, and with DXA, the projection BMD is assessed. The approaches to the interpretation of the results are also different - diagnosis of OP in DXA of the spine based on the T-score, but in QCT, the ACR (American College of Radiology) criteria are used.We describe the phantoms used in QCT, as well as provide data on radiation exposure during QCT and DXA.The article describes an approach to opportunistic screening of osteoporosis by the QCT based on the results of previously performed CT scans, including its automated work-flow using artificial intelligence technologies. These promising techniques are attractive due to the large number of CT examinations performed and the exclusion of additional examinations.

Publisher

Vidar, Ltd.

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3