Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.

Author:

Mansfield E S,Vainer M,Enad S,Barker D L,Harris D,Rappaport E,Fortina P

Abstract

The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high throughput, and sensitive detection. To assess the utility of CAE for the accumulation of genetic information, we tested both sizing accuracy and reproducibility using 48-capillary prototype systems. Two multiplex PCR allelic ladder standards and several CA-repeat markers were analyzed in > 100 runs. Reproducibility in typing > 8000 genotypes reveals a standard deviation of less than 0.2 bp on these systems under optimized conditions. However, sequence-dependent migration anomalies were observed at most simple sequence loci even when analyzed under denaturing conditions, resulting in a systematic bias in estimated fragment sizes. We show here that, by normalizing results to known typing controls, one can obtain locus-averaged accuracies of < 0.06 bp and normalized results within 1 bp of actual. We detect as little as a 1:30,000 dilution of a DNA quantitation standard stained with highly sensitive intercalating dyes, indicating an 80-zeptomole sensitivity limit. However, to obtain reproducible electrokinetic injection, approximately 200 attomoles of fluorescein-labeled DNA is required. These sensitivity limits, sizing precision, and accuracy, together with the 1-hr run times for 48-96 samples, indicate that CAE is a viable method for high-throughput genetic analysis of simple sequence repeat polymorphisms.

Publisher

Cold Spring Harbor Laboratory

Subject

Genetics(clinical),Genetics

Reference33 articles.

1. DNA sequencing by capillary electrophoresis with a hydroxyethylcellulose sieving buffer.;Appl. Theoret. Electrophoresis,1996

2. Bashkin, J., Roach, D. Leong, J. Barker, D. and Johnston. R. 1996b. Implementation of a capillary array electrophoresis instrument. J. Capil. Electrophoresis (in press).

3. Butler, J.M. 1995. Sizing and quantitation of polymerase chain reaction products by capillary electrophoresis for use in DNA typing. Ph.D. dissertation, University of Virginia, Charlottesville, VA.

4. Triplet Repeat Mutations in Human Disease

5. Anomalous Rapid Electrophoretic Mobility of DNA Containing Triplet Repeats Associated with Human Disease Genes

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3