Author:
Modak Nirmoy,Nath Mayukh,Chatterjee Baibhab,Maity Shovan,Sen Shreyas
Abstract
AbstractHuman Body Communication (HBC) is an alternative to radio wave-based Wireless Body Area Network (WBAN) because of its low-loss, wide bandwidth leading to enhanced energy efficiency. HBC also shows better performance in terms of physical security as most of the signal is confined within the body. To obtain optimum performance and usability, modeling of the body channel plays a vital role. Out of two HBC modalities, Galvanic HBC has the promise to provide lower loss compare to Capacitive HBC for shorter channel length. In this paper, we present the first lumped element based detailed model of Galvanic HBC channel which is used to explain the dependency of channel loss on the material property of skin, fat and muscle tissue layer along with electrode size, electrode separation, geometrical position of the electrodes and return path capacitance. The model considers the impedance of skin and muscle tissue layers and the effect of various coupling capacitances between the body and Tx/Rx electrodes to the Earth-ground. A 2D planner structure is simulated in HFSS to prove the validity of the proposed model. The effect of symmetry and asymmetry at the transmitter and receiver end are also explained using the model. The experimental results show that, due to the mismatch at the transmitter and receiver side, the loss increases gradually with channel length and saturates to a finite value as channel length becomes significantly longer compare to the transmitting or receiving electrode pair separation.
Publisher
Cold Spring Harbor Laboratory
Reference17 articles.
1. Personal Area Networks: Near-field intrabody communication
2. X. Wang , J. Shi , L. Xu , and J. Wang , “A Wideband Miniaturized Implantable Antenna for Biomedical Application at HBC Band,” in 2018 Cross Strait Quad-Regional Radio Science and Wireless Technology Conference (CSQRWC), Jul. 2018, pp. 1–3.
3. N. Fahier and W. Fang , “An HBC-based continuous bio-potential system monitoring using 30mhz OOK modulation,” in 2017 IEEE Biomedical Circuits and Systems Conference (BioCAS), Oct. 2017, pp. 1–4.
4. F. Koshiji , R. Urushidate , and K. Koshiji , “Biomedical signal trans-mission using human body communication,” in 2017 IEEE 36th In-ternational Performance Computing and Communications Conference (IPCCC), Dec. 2017, pp. 1–2.
5. J. Wang , T. Fujiwara , T. Kato , and D. Anzai , “Wearable ECG Based on Impulse-Radio-Type Human Body Communication,” IEEE Transactions on Biomedical Engineering, vol. 63, no. 9, pp. 1887–1894, Sep. 2016.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献