Chromatographic Techniques for Assessment of Bisoprolol Fumarate and Perindopril Arginine in Solid Formulations under Various Stress Conditions and Application to Six Sigma, Content Uniformity, and Comparative Dissolution Approaches

Author:

Mahmoud Osama A1,Omran Ahmed A2,Binsaleh Ammena Y3ORCID,Almalki Manal A4,Mohamed Mahmoud A5ORCID

Affiliation:

1. Penta Pharma Egypt , Ismailia 41527, Egypt

2. Al-Azhar University, Faculty of Science (Men’s Campus), Department of Chemistry , Nasr City, Cairo 11884, Egypt

3. Princess Nourah bint Abdulrahman University, Department of Pharmacy Practice, College of Pharmacy , PO Box 84428, Riyadh 11671, Saudi Arabia

4. Taibah University, Chemistry Department, College of Science , Al-Madinah Al Munawarah, Al-Madina 30002, Saudi Arabia

5. Hikma Pharmaceutical Company , Beni-Suef 62511, Egypt

Abstract

Abstract Background Antihypertensives bisoprolol fumarate (BIS) and perindopril arginine (PER) were simultaneously determined in their pure, bulk, and combined tablet dosage form. Objective This study develops a novel, reproducible, and accurate Reversed phase high-performance liquid chromatography (RP-HPLC) and Reversed phase ultra-performance liquid chromatography (RP-UPLC) with photodiode array detection techniques, which were then applied to in vitro dissolution studies. Methods The first RP-HPLC method relied on isocratic elution using a mobile phase of methanol–0.05 M phosphate buffer pH 2.6 (1 + 1, by volume), and separation was performed using a Thermo Hypersil C8 column (150 mm × 4.6 mm, 5 μm). Ion-pair UPLC was the second method. An acceptable resolution was achieved using an RP-C18 chromatographic column, Agilent Eclipse (100 × 2.1 mm, 1.7 μm), with a mobile phase containing 0.005 M sodium 1-heptane sulfonate–triethylamine (64 + 1 + 35, by volume), adjusted with phosphoric acid to a pH of 2.0. RP-HPLC used a 1.0 mL/min flow rate, while UPLC used 0.5 mL/min, and the two methods used detection at 210 nm. Results Calibration curves of BIS and PER were linear for RP-HPLC and RP-UPLC methods at 0.5-15 and 0.5-40 μg/mL, respectively. BIS and PER had RP-UPLC LODs of 0.22 and 0.10 μg/mL, respectively, and LOQs of 0.68 and 0.31 μg/mL, respectively. As a result, the approach has been effectively applied to in vitro dissolution testing for drugs in generic and reference products, showing that the two products are comparable. The Six Sigma approach was implemented to compare the recommended and United States Pharmacopeia (USP) procedures, which both exhibited process capability index (Cpk) >1.33. A content uniformity test demonstrated that the drugs in their dosage form met the acceptance limit (85–115%). The degradation products were reliably distinguished from pure drugs for a range of retention times. Conclusion In their commercial drug product, the proposed method could be used in QC laboratories for concurrent testing, content uniformity, and in vitro dissolution investigations of BIS and PER. The methods were successfully validated per International Council for Harmonisation (ICH) guidelines. Highlights This study is innovative since it is the first to establish and validate specific and reproducible UPLC and HPLC methods for the concurrent quantitation of the studied drugs in their binary mixture and application to lean Six Sigma, content uniformity, and comparative dissolution approaches.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3