Preoperative Magnetic Resonance and Intraoperative Computed Tomography Fusion for Real-Time Neuronavigation in Intramedullary Lesion Surgery

Author:

Costa Francesco1,Ortolina Alessandro1,Cardia Andrea1,Riva Marco1,Revay Martina1,Pecchioli Guido1,Anania Carla Daniela1,Asteggiano Francesco2,Fornari Maurizio1

Affiliation:

1. Departments of Neurosurgery, Humani-tas Clinical and Research Center, Rozzano (MI), Italy

2. Departments of Radiology, Humanitas Clinical and Research Center, Rozzano (MI), Italy

Abstract

Abstract BACKGROUND: Image-guided surgery techniques in spinal surgery are usually based upon fluoroscopy or computed tomography (CT) scan, which allow for a real-time navigation of bony structures, though not of neural structures and soft tissue remains. OBJECTIVE: To verify the effectiveness and efficacy of a novel technique of imaging merging between preoperative magnetic resonance imaging (MRI) and intraoperative CT scan during removal of intramedullary lesions. METHODS: Ten consecutive patients were treated for intramedullary lesions using a navigation system aid. Preoperative contrast-enhanced MRI was merged in the navigation software, with an intraoperative CT acquisition, performed using the O-armTM system (Medtronic Sofamor Danek, Minneapolis, Minnesota). Dosimetric and timing data were also acquired for each patient. RESULTS: The fusion process was achieved in all cases and was uneventful. The merged imaging information was useful in all cases for defining the exact area of laminectomy, dural opening, and the eventual extension of cordotomy, without requiring exposition corrections. The radiation dose for the patients was 0.78 mSv. Using the authors’ protocol, it was possible to merge a preoperative MRI with navigation based on intraoperative CT scanning in all cases. Information gained with this technique was useful during the different surgical steps. However, there were some drawbacks, such as the merging process, which still remains partially manual. CONCLUSION: In this initial experience, MRI and CT merging and its feasibility were tested, and we appreciated its safety, precision, and ease.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3