Verification of Harmonization of Serum Total and Free Prostate-Specific Antigen (PSA) Measurements and Implications for Medical Decisions

Author:

Ferraro Simona1,Bussetti Marco1,Rizzardi Sara2,Braga Federica13,Panteghini Mauro13

Affiliation:

1. Unità Operativa Complessa di Patologia Clinica, ASST Fatebenefratelli-Sacco, Milano, Italy

2. Unità Operativa Laboratorio Analisi Chimico Cliniche e Microbiologiche, ASST Cremona, Cremona, Italy

3. Research Centre for Metrological Traceability in Laboratory Medicine (CIRME), University of Milan, Milan, Italy

Abstract

Abstract Background Previous studies have shown that the harmonization of prostate-specific antigen (PSA) assays remained limited even after the introduction of WHO International Standards. This information needs updating for current measuring systems (MS) and reevaluation according to established analytical performance specifications (APS) and the characteristics of antibodies used. Methods Total (tPSA) and free (fPSA) PSA were measured in 135 and 137 native serum samples, respectively, by Abbott Alinity i, Beckman Access Dxl, Roche Cobas e801, and Siemens Atellica IM MSs. Passing–Bablok regression and difference plots were used to compare results from each MS to the all-method median values. Agreement among methods was evaluated against APS for bias derived from biological variation of the 2 measurands. Results The median interassay CV for tPSA MSs (11.5%; 25–75th percentiles, 9.2–13.4) fulfilled the minimum APS goal for intermethod bias (15.9%), while the interassay CV for fPSA did not [20.4% (25–75th percentiles, 18.4–22.7) vs goal 17.6%]. Considering the all-method median value of each sample as reference, all tPSA MSs exhibited a mean percentage bias within the minimum goal. On the other hand, Alinity (+21.3%) and Access (−24.2%) were out of the minimum bias goal for fPSA, the disagreement explained only in minimal part by the heterogeneity of employed antibodies. Conclusions The harmonization among tPSA MSs is acceptable only when minimum APS are applied and necessitates further improvement. The marked disagreement among fPSA MSs questions the use of fPSA as a second-level test for biopsy referral.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3