Comparison of 6 Automated Assays for Total and Free Prostate-Specific Antigen with Special Reference to Their Reactivity toward the WHO 96/670 Reference Preparation

Author:

Kort Sheila AR1,Martens Frans1,Vanpoucke Hilde2,van Duijnhoven Hans L3,Blankenstein Marinus A1

Affiliation:

1. Endocrine Laboratory, Department of Clinical Chemistry, VU University Medical Center, Amsterdam, The Netherlands

2. Laboratory of Clinical Chemistry, H. Hartziekenhuis, Roeselare-Menen vzw, Belgium

3. Algemeen Klinisch Laboratorium, Elkerliek Ziekenhuis, Helmond, The Netherlands

Abstract

Abstract Background: Prostate-specific antigen (PSA) assays have historically produced different results. Our aim was to investigate the comparability of assay results of selected commercially available assay methods designed to measure total, free, or complexed PSA (tPSA, fPSA, and cPSA). Methods: We measured tPSA, fPSA, and cPSA in 70 samples and in the WHO PSA 96/670 reference preparation with 6 assays (Beckman-Coulter Access, Abbott ARCHITECT and AxSYM, Bayer Advia Centaur, DPC IMMULITE 2000, and Roche Modular Analytics E170). We also calculated the fPSA/tPSA ratio. Results: The mean deviations from the expected tPSA and fPSA values for the WHO 96/670 reference preparation were 0.37 (range, 0.01–1.32) and 0.19 (range, 0.05–0.49) μg/L, respectively. When plotted against the expected WHO 96/670 reference preparation value, regression slopes varied from 0.99 to 1.22 and r2 from 0.9996 to 1.000. When total PSA was measured in mixtures of sera with high and low tPSA concentrations, the mean (SD) slope of regression of different assays against an in-house method was 1.04 (0.09). In these specimens, the fPSA/tPSA ratio was 0.11–0.14 with different methods. The tPSA and fPSA values in patient samples measured in different assays and plotted against ARCHITECT gave regression slopes from 0.88 to 0.97. The results of the studied assays for tPSA in serum samples agreed within 15%, from each other, and all results for the WHO 96/670 reference preparation were within 6.8% (confidence interval, 1.7%–15.2%) of the expected value. The results for fPSA were more diverse. Conclusions: Differences among PSA assays appear to have decreased since introduction of the WHO 96/670 reference preparation, but further efforts are needed to harmonize fPSA assays.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3