Charles B G,Jacobsen N W,Ravenscroft P J
Abstract
Abstract
We describe an analysis for metformin in plasma and urine by use of cation-exchange "high-performance" liquid chromatography. The assay requires only 0.5 mL of sample and involves pretreatment with trichloroacetic acid containing an internal standard (1-propylbiguanide), followed by centrifugation and injection into the chromatograph. The column eluent is monitored at 230 nm. Metformin and 1-propylbiguanide give retention times of 8 and 10 min, respectively. Within-day and between-day precision (CV) for the assay of plasma containing 2 mg (1.2 X 10(-5) mol) of metformin hydrochloride per liter was 3.6 and 3.9%, respectively. Similar precision was obtained for urine. The limit of detection is about 0.1 mg (6.0 X 10(-7) mol) of metformin hydrochloride per liter. Several commonly used drugs, including other oral hypoglycemic agents, do not interfere with this method.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry (medical),Clinical Biochemistry
Cited by
42 articles.