Author:
Gotelli G R,Kabra P M,Marton L J
Abstract
Abstract
We describe a sensitive and precise high-pressure liquid chromatographic method in which acetoacetanilide is used as the internal standard to simultaneously determine acetaminophen and phenacetin in plasma. Therapeutic as well as toxic concentrations can be determined on as little as 0.1 ml of plasma. Sample preparation is rapid and chromatography is complete in 5 min. Quantitation is accurate at 0.5 mg/liter concentration for both drugs. Day-to-day precision within 5% is attainable. Of 36 other drugs tested, only theophylline interfered, with the determination of acetaminophen.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry (medical),Clinical Biochemistry
Cited by
42 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献