Development of a Routine Method for the Determination of Trace Metals in Whole Blood by Magnetic Sector Inductively Coupled Plasma Mass Spectrometry with Particular Relevance to Patients with Total Hip and Knee Arthroplasty

Author:

Case C Patrick1,Ellis Lyndon2,Turner Justine C3,Fairman Ben3

Affiliation:

1. University Department of Orthopaedic Surgery, Department of Histopathology, Southmead Hospital, Southmead Road, Bristol B510 5NB, UK

2. Department of Earth Sciences, Queens Road University of Bristol, Bristol BS8 1RJ, UK

3. LGC (Teddington) Ltd., Queens Road, Teddington, Middlesex TW11 0LY, UK

Abstract

Abstract Background: Joint-replacement surgery has revolutionized the treatment of osteoarthritis and is still the most effective therapy. A recent clinical trend reintroducing metal-on-metal bearing surfaces has in turn stimulated a requirement for accurate measurement of the concentrations of relevant metals in both pre- and postoperative patients. Thus, there is a need for cost-effective, multielement methods for trace metal analysis in whole blood to monitor possible increases in wear metal concentrations. Methods: A method was developed to allow routine analysis of whole blood samples for molybdenum, cobalt, chromium, and nickel. Sample preparation consisted of a simple 1:10 dilution of whole blood with a solution of 10 mL/L Triton X-100, 0.0002 mol/L EDTA, and 0.01 mol/L ammonium hydroxide. Final determination was performed by a double-focusing magnetic sector inductively coupled plasma mass spectrometer operated in medium-resolution mode (resolution, 3400). Online addition of rhodium was used for internal standardization. Results: Detection limits in whole blood were 0.06 μg/L for chromium, cobalt, and molybdenum and 0.30 μg/L for nickel. Base concentrations of 0.22, 0.17, 0.62, and 0.99 μg/L for chromium, cobalt, molybdenum, and nickel, respectively, in whole blood have been found. Polyatomic interferences on all four elements have been shown to be resolved from the analyte masses by use of a resolution of >3000. Conclusions: The simple, rapid method of sample preparation is effective in minimizing potential contamination and enables 60 samples (run time, 8 h) to be analyzed before cleaning the instrument is necessary. A resolution >3000 was sufficient to separate polyatomic interferences from the masses of interest. The method was used to analyze a large number of blood samples taken from primary patients awaiting total hip arthroplasty. The method is sensitive enough to provide base concentrations for chromium, cobalt, and molybdenum in whole blood. The results for nickel were compromised by high signals for blank samples.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 74 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3