Detection of Early Pregnancy Forms of Human Chorionic Gonadotropin by Home Pregnancy Test Devices

Author:

Butler Stephen A1,Khanlian Sarah A1,Cole Laurence A1

Affiliation:

1. USA hCG Reference Service, Obstetrics and Gynecology, University of New Mexico, Albuquerque, NM 87131

Abstract

Abstract Background: Home pregnancy testing devices claim >99% diagnostic accuracy for pregnancy and utility on the first day of the missed menses or earlier. We investigated the forms of human chorionic gonadotropin (hCG) in early pregnancy urines, the diagnostic accuracy claim, and the abilities of 15 devices to detect the different forms of hCG. Methods: We measured the concentrations of regular hCG and hyperglycosylated hCG (H-hCG, a large hCG variant) in 592 urines. Fifteen home devices were tested according to manufacturers’ instructions with regular hCG and H-hCG diluted in urine. Results: H-hCG was the principal hCG-related molecule in pregnancy urine in the 2 weeks following the missed menses (61% and 50% of total immunoreactivity in the 4th and 5th completed weeks of pregnancy, respectively). Of 15 home test devices, 2 had a detection limit of 6.3 IU/L for regular hCG, but poorer detection of H-hCG. Two devices detected 13 IU/L regular hCG, one with similar detection and one with poorer detection of H-hCG. Ten devices detected 25 IU/L regular hCG, 6 with poorer detection of H-hCG. One device detected 50 IU/L regular hCG, but better detected H-hCG. Overall, 9 of 15 devices did not detect H-hCG as well as regular hCG. Conclusions: H-hCG is the principal hCG immunoreactivity in early pregnancy urine. Home tests vary widely in detection limits for regular hCG (6.3–50 IU/L), and 9 of 15 devices (60%) had poorer detection limits for H-hCG than for hCG. The variation in analytical detection limits appears contradictory to the common claim for all devices of >99% detection of pregnancy on the first day of the missed menses or earlier. We suggest that manufacturers calibrate devices for both hCG and H-hCG and determine the detection rates for pregnancy rather than the proportion of positive results at arbitrary hCG concentrations.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3