Secondary cancer risk from modern external-beam radiotherapy of prostate cancer patients: Impact of fractionation and dose distribution

Author:

Sitathanee Chomporn1,Tangboonduangjit Puangpen1,Dhanachai Mantana1,Suntiwong Sawanee1,Yongvithisatid Pornpan1,Rutchantuk Sukanya1,Changkaew Pimolpun1,Watjiranon Rattana1,Khachonkham Suphalak1,Boonkitticharoen Vipa1

Affiliation:

1. Department of Diagnostic and Therapeutic Radiology, Faculty of Medicine Ramathibodi Hospital, Mahidol University, Bangkok 10400, Thailand

Abstract

Abstract Modern radiotherapy (RT) uses altered fractionation, long beam-on time and image-guided procedure. This study aimed to compare secondary cancer risk (SCR) associated with primary field, scatter/leakage radiations and image-guided procedure in prostate treatment using intensity-modulated RT (IMRT), CyberKnife stereotactic body RT (CK-SBRT) in relative to 3-dimensional conformal RT (3D-CRT). Prostate plans were generated for 3D-CRT, IMRT (39 fractions of 2 Gy), and CK-SBRT (five fractions of 7.25 Gy). Excess absolute risk (EAR) was calculated for organs in the primary field using Schneider’s mechanistic model and concept of organ equivalent dose (OED) to account for dose inhomogeneity. Doses from image-guided procedure and scatter/leakage radiations were determined by phantom measurements. The results showed that hypofractionation relative to conventional fractionation yielded lower SCR for organs in primary field (p ≤ 0.0001). SCR was further modulated by dose-volume distribution. For organs near the field edge, like the rectum and pelvic bone, CK-SBRT plan rendered better risk profiles than IMRT and 3D-CRT because of the absence of volume peak in high dose region (relative risk [RR]: 0.65, 0.22, respectively, p ≤ 0.0004). CK-SBRT and IMRT generated more scatter/leakage and imaging doses than 3D-CRT (p ≤ 0.0002). But primary field was the major contributor to SCR. EAR estimates (risk contributions, primary field: scatter/leakage radiations: imaging procedure) were 7.1 excess cases per 104 person–year (PY; 3.64:2.25:1) for CK-SBRT, 9.93 (7.32:2.33:1) for IMRT and 8.24 (15.99:2.35:1) for 3D-CRT (p ≤ 0.0002). We conclude that modern RT added more but small SCR from scatter/leakage and imaging doses. The primary field is a major contributor of risk which can be mitigated by the use of hypofractionation.

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3