Fluorescent Antibody Method for the Detection of Salmonella: Development, Evaluation, and Collaborative Study

Author:

Fantasia Leonard D1,Schrade John P1,Yager James F1,Debler Diane1

Affiliation:

1. Food and Drug Administration, 850 Third Ave., Brooklyn, NY 11232

Abstract

Abstract In preliminary studies, several commercial polyvalent fluorescent antibody (FA) preparations were evaluated for specificity and crossreactivity and an FA method was developed for the screening of Salmonella in products. Approximately 4000 product samples were tested by the FA method and the results were compared to those from the official final action AOAC method, 46.013–46.026. Only 4 FA falsenegatives were found for a total of 619 confirmed positive Salmonella samples. The FA false-positive rate was 7%. The method was then subjected to a 2-phase collaborative study. In Phase I, 22 analysts tested 5 inoculated and 5 uninoculated samples of dried milk. In Phase II, 5 naturally contaminated and 5 presumably uncontaminated foods were analyzed. The study was designed to compare results from 11 analysts experienced in FA methodology with those from 11 analysts with little or no experience. Selenite cystine (SC) and tetrathionate (TT) broths were used for enrichment and both were inoculated into SC for post-enrichment. All 4 combinations (SC, TT, SC-SC, and TT-SC) were used with the FA method to determine the best technique. Results were compared to the analysis with TT and SC by the AOAC culture method. In all studies, FA analysis with SC-SC gave the highest correlation with the AOAC method. In a total of 200 samples, the experienced group found 125 AOAC positives and 127 FA positives ; no FA false-negatives and only 2 falsepositives were reported. The inexperienced group reported 9 FA false-negatives and 5 FA false-positives. All false-negatives occurred in only 3 of the inexperienced laboratories. These studies showed that enrichment and post-enrichment in SC gave the best FA results and that training in FA methodology is required for correlation with existing AOAC methodology. The FA method for the detection of Salmonella has been adopted as official first action.

Publisher

Oxford University Press (OUP)

Subject

General Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3