A novel non-invasive and echocardiography-derived method for quantification of right ventricular pressure–volume loops

Author:

Richter Manuel J1,Yogeswaran Athiththan1,Husain-Syed Faeq1,Vadász István1,Rako Zvonimir1,Mohajerani Emad1,Ghofrani Hossein A123,Naeije Robert4,Seeger Werner15,Herberg Ulrike6,Rieth Andreas7,Tedford Ryan J8,Grimminger Friedrich59,Gall Henning1,Tello Khodr1

Affiliation:

1. Department of Internal Medicine, Justus-Liebig-University Giessen, Universities of Giessen and Marburg Lung Center (UGMLC), Member of the German Center for Lung Research (DZL), Klinikstrasse 32, Giessen 35392, Germany

2. Department of Pneumology, Kerckhoff Heart, Rheuma and Thoracic Center, Benekestr. 2–8, Bad Nauheim 61231, Germany

3. Department of Medicine, Imperial College London, Level 2, Faculty Building, South Kensington Campus, London SW7 2AZ, UK

4. Erasme University Hospital, Route de Lennik 808, Brussels 1070, Belgium

5. Department of Internal Medicine, German Center for Lung Research (DZL), Cardio-Pulmonary Institute (CPI), Justus-Liebig-University Giessen, Aulweg 130, Giessen 35392, Germany

6. Department of Pediatric Cardiology, University of Bonn, Building 30, Venusberg-Campus 1, Bonn 53127, Germany

7. Department of Thoracic Surgery, Kerckhoff Heart, Rheuma and Thoracic Center, Benekestr. 2–8, 61231 Bad Nauheim, Germany

8. Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, USA

9. Institute for Lung Health (ILH), Justus-Liebig-University Giessen, Giessen, Germany

Abstract

Abstract Aims We sought to assess the feasibility of constructing right ventricular (RV) pressure–volume (PV) loops solely by echocardiography. Methods and results We performed RV conductance and pressure wire (PW) catheterization with simultaneous echocardiography in 35 patients with pulmonary hypertension. To generate echocardiographic PV loops, a reference RV pressure curve was constructed using pooled PW data from the first 20 patients (initial cohort). Individual pressure curves were then generated by adjusting the reference curve according to RV isovolumic and ejection phase duration and estimated RV systolic pressure. The pressure curves were synchronized with echocardiographic volume curves. We validated the reference curve in the remaining 15 patients (validation cohort). Methods were compared with correlation and Bland–Altman analysis. In the initial cohort, echocardiographic and conductance-derived PV loop parameters were significantly correlated {rho = 0.8053 [end-systolic elastance (Ees)], 0.8261 [Ees/arterial elastance (Ea)], and 0.697 (stroke work); all P < 0.001}, with low bias [−0.016 mmHg/mL (Ees), 0.1225 (Ees/Ea), and −39.0 mmHg mL (stroke work)] and acceptable limits of agreement. Echocardiographic and PW-derived Ees were also tightly correlated, with low bias (−0.009 mmHg/mL) and small limits of agreement. Echocardiographic and conductance-derived Ees, Ees/Ea, and stroke work were also tightly correlated in the validation cohort (rho = 0.9014, 0.9812, and 0.9491, respectively; all P < 0.001), with low bias (0.0173 mmHg/mL, 0.0153, and 255.1 mmHg mL, respectively) and acceptable limits. Conclusion The novel echocardiographic method is an acceptable alternative to invasively measured PV loops to assess contractility, RV-arterial coupling, and RV myocardial work. Further validation is warranted.

Funder

Deutsche Forschungsgemeinschaft

German Research Foundation

Publisher

Oxford University Press (OUP)

Subject

Cardiology and Cardiovascular Medicine,Radiology, Nuclear Medicine and imaging,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3