Artificial intelligence-enabled reconstruction of the right ventricular pressure curve using the peak pressure value: a proof-of-concept study

Author:

Szijártó Ádám,Nicoara Alina,Podgoreanu Mihai,Tokodi Márton,Fábián Alexandra,Merkely Béla,Sárkány András,Tősér Zoltán,Lakatos Bálint,Kovács AttilaORCID

Abstract

AbstractConventional echocardiographic parameters of right ventricular (RV) function are heavily afterload-dependent. Therefore, the incorporation of the RV pressure curve may enable the formulation of new parameters that reflect intrinsic RV function more accurately. Accordingly, we sought to develop an artificial intelligence-based method that can reconstruct the RV pressure curve based on the peak RV pressure.We invasively acquired RV pressure in 29 heart failure patients before and after the implantation of a left ventricular (LV) assist device. Using these tracings, we trained various machine learning models to reconstruct the RV pressure curve of the entire cardiac cycle solely based on the peak value of the invasively acquired curve. The best-performing model was compared with the performance of two other methods that estimated RV pressure curves based on a reference LV and RV pressure curve, respectively.Among the evaluated algorithms, the multilayer perceptron (MLP) achieved the best performance with an R2of 0.887 [0.834 – 0.941]. The RV and LV reference curve-based methods achieved R2values of 0.879 [0.815 – 0.943] and 0.636 [0.500 – 0.771], respectively. The MLP and the RV reference curve-based estimation showed good agreement with the invasive RV pressure curves (mean bias: -0.38 mmHg and -0.73 mmHg, respectively), whereas the LV reference curve-based estimation exhibited a high mean bias (+3.93 mmHg).The proposed method enables the reconstruction of the RV pressure curve, using only the peak value as input. Thus, it may serve as a fundamental component for developing new echocardiographic tools targeting the afterload-adjusted assessment of RV function.Graphical abstractKey question. Can artificial intelligence be useful in the reconstruction of the right ventricular pressure curve of the entire cardiac cycle using only the peak value as input?Key findings. Multilayer Perceptron predicted instantaneous pressure values with a balanced, low bias throughout the cardiac cycle, even slightly outperforming the reference curve creation methods.Take-home message. Accurate prediction of the right ventricular pressure curve may enable formulation of new echocardiographic parameters targeting the afterload-adjusted assessment of RV function.LV: left ventricular, PVC: pulmonary valve closure, PVO: pulmonary valve opening, RV: right ventricular, TVC: tricuspid valve closure, TVO: tricuspid valve opening

Publisher

Cold Spring Harbor Laboratory

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3