Maximal Dynamic Inspiratory Pressure Evaluation in Heart Failure: A Comprehensive Reliability and Agreement Study

Author:

da Silva Fabiola M F1,Cipriano Gerson2,Lima Alexandra C G B3,Andrade Joanlise M L4,Nakano Eduardo Y4,Chiappa Gaspar R5,Cahalin Lawrence P6,Cipriano Graziella F B7

Affiliation:

1. Science and Technology in Health Program, University of Brasília, Brasília, Brazil

2. Science and Technology in Health Program and Physical Therapy Department, Science of Rehabilitation Program, University of Brasília

3. Science and Technology in Health Program, University of Brasília

4. Department of Statistics, University of Brasília

5. Respiratory and Pathology Laboratory, Federal University of Mato Grosso do Sul, Mato Grosso do Sul, Brazil

6. Physical Therapy Department and Leonard M. Miller School of Medicine, University of Miami, Coral Gables, Florida

7. Science and Technology in Health Program and Physical Therapy Department, Science of Rehabilitation Program, University of Brasília, QNN 14 Área Especial, Ceilândia Sul, CEP 72220-140, Brasília, Brazil

Abstract

Abstract Objective The purpose of this study was to analyze the reliability (interrater and intrarater) and agreement (repeatability and reproducibility) properties of tapered flow resistive loading (TFRL) measures in patients with heart failure (HF). Methods For this cross-sectional study, participants were recruited from the cardiopulmonary rehabilitation program at the University of Brasilia from July 2015 to July 2016. All patients participated in the study, and 10 were randomly chosen for intrarater and interrater reliability testing. The 124 participants with HF (75% men) were 57.6 (SD = 1.81) years old and had a mean left ventricular ejection fraction of 38.9% (SD = 15%) and a peak oxygen consumption of 13.05 (SD = 5.3) mL·kg·min−1. The main outcome measures were the maximal inspiratory pressure (MIP) measured with a standard manovacuometer (SM) and the MIP and maximal dynamic inspiratory pressure (S-Index) obtained with TFRL. The S-Index reliability (interrater and intrarater) was examined by 2 evaluators, the S-Index repeatability was examined with 10 repetitions, and the reproducibility of the MIP and S-Index was measured with SM and TFRL, respectively. Results The reliability analysis revealed high S-Index interrater and intrarater reliability values (intraclass correlation coefficients [ICCs] of 0.89 [95% CI = 0.58–0.98] and 0.97 [95% CI = 0.89–0.99], respectively). Repeatability analyses revealed that 8 maneuvers were required to reach the maximum S-Index in 75.81% (95% CI = 68.27–83.34) of the population. The reproducibility of TFRL measures (S-Index = 68.8 [SD = 32.8] cm H2O; MIP = 66 [SD = 32.3] cm H2O) was slightly lower than that of the SM measurement (MIP = 70.1 [SD = 35.9] cm H2O). Conclusions The TFRL device provided a reliable intrarater and interrater S-Index measure in patients with HF and had acceptable repeatability, requiring 8 maneuvers to produce a stable S-Index measure. The reproducibilities of the S-Index, MIP obtained with SM, and MIP obtained with TRFL were similar. Impact TRFL is a feasible method to assess both MIP and the S-index as measures of inspiratory muscle strength in patients with HF and can be used for inspiratory muscle training, making the combined testing and training capabilities important in both clinical research and the management of patients with HF.

Publisher

Oxford University Press (OUP)

Subject

Physical Therapy, Sports Therapy and Rehabilitation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3