Preliminary comparison of the registration effect of 4D-CBCT and 3D-CBCT in image-guided radiotherapy of Stage IA non–small-cell lung cancer

Author:

Tan Zhibo12,Liu Chuanyao3,Zhou Ying4,Shen Weixi1

Affiliation:

1. Department of Oncology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao'an District, Shenzhen 518110, Guangdong Province, PR China

2. Department of Radiation Oncology, Sichuan Cancer Hospital, #55 Renmin Road South, Wuhou District, Chengdu 610041, Sichuan Province, PR China

3. Department of Rehabilitation, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao'an District, Shenzhen 518110, Guangdong Province, PR China

4. Department of Oncology and Hematology, Shenzhen Hospital of Southern Medical University, #1333 Xinhu Road, Bao'an District, Shenzhen 518110, Guangdong Province, PR China

Abstract

Abstract In this study, we compared the registration effectiveness of 4D cone-beam computed tomography (CBCT) and 3D-CBCT for image-guided radiotherapy in 20 Stage IA non–small-cell lung cancer (NSCLC) patients. Patients underwent 4D-CBCT and 3D-CBCT immediately before radiotherapy, and the X-ray Volume Imaging software system was used for image registration. We performed automatic bone registration and soft tissue registration between 4D-CBCT or 3D-CBCT and 4D-CT images; the regions of interest (ROIs) were the vertebral body on the layer corresponding to the tumor and the internal target volume region. The relative displacement of the gross tumor volume between the 4D-CBCT end-expiratory phase sequence and 4D-CT was used to evaluate the registration error. Among the 20 patients (12 males, 8 females; 35–67 years old; median age, 52 years), 3 had central NSCLC and 17 had peripheral NSCLC, 8 in the upper or middle lobe and 12 in the lower lobe (maximum tumor diameter range, 18–27 mm). The internal motion range in three-dimensional space was 12.52 ± 2.65 mm, accounting for 47.8 ± 15.3% of the maximum diameter of each tumor. The errors of image-guided registration using 4D-CBCT and 3D-CBCT on the x (left–right), y (superior–inferior), z (anterior–posterior) axes, and 3D space were 0.80 ± 0.21 mm and 1.08 ± 0.25 mm, 2.02 ± 0.46 mm and 3.30 ± 0.53 mm, 0.52 ± 0.16 mm and 0.85 ± 0.24 mm, and 2.25 ± 0.44 mm and 3.59 ± 0.48 mm (all P < 0.001), respectively. Thus, 4D-CBCT is preferable to 3D-CBCT for image guidance in small pulmonary tumors because 4D-CBCT can reduce the uncertainty in the tumor location resulting from internal motion caused by respiratory movements, thereby increasing the image-guidance accuracy.

Publisher

Oxford University Press (OUP)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Radiation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3